1 / 4 · Click to enlarge
AI Summary
A 12V DC normally closed solenoid valve with 1/2 inch hose barbs that opens only while powered. It handles water, oil or air at 0.02-0.8MPa, making it a simple fit for automated fluid control.
Key Highlights
- Normally closed design opens only while 12V DC is applied
- 1/2 inch hose barb inlet and outlet for direct hose connection
- 8W coil drawing around 1A at 12VDC
- Works with water, oil and air up to 100 degrees C
- Handles line pressures from 0.02 to 0.8MPa
- Compact 84 x 57mm body weighing about 100g
Ideal For
- Robotic gardening and automated irrigation builders
- DIY fluid control and hydroponics projects
- Small pneumatic and air line automation
- Makers using 12V relays or controllers
- Oil and water transfer setups needing a powered shutoff
Buying Tip
Check that your supply can deliver about 1A at 12V and that your line is pressurised within 0.02-0.8MPa, since this valve is not suitable for gravity fed systems.
Elecvora expert review
Our verdict
A straightforward, low-cost valve for anyone who needs a 12V-triggered shutoff on a pressurised water, oil or air line. It is simple to wire and hose up, though the intermittent coil rating and pressure requirement limit it to planned, non-continuous duties.
AI-assisted analysis based on the manufacturer's specifications. Not a hands-on lab test.
Pros
- Simple two-wire 12V control
- Normally closed safe state when unpowered
- Handles water, oil and air
- Compact and light at about 100g
- Installs at any angle
Cons
- Not suitable for gravity fed systems
- Coil is rated for intermittent energised use
- Requires a pressurised line within 0.02-0.8MPa
Best for
Makers automating pressurised water, oil or air lines with a 12V trigger
Not ideal for
Unpressurised gravity fed watering setups or continuous-duty flow control
Specifications
| Item Type | Normally Closed |
|---|---|
| Voltage Rating (V) | 12VDC |
| Current Rating (A) | 1 |
| Operating Voltage (VDC) | 12 |
| Operation Mode | Normally Closed |
| Power Consumption (W) | 8 |
| Pressure | 0.02- 0.8Mpa |
| Energized forms | Intermittent |
| Inlet & Outlet Diameter | Hose barbs for 1/2" (outer diameter) hose |
| Max fluid temperature | 100°C |
| Dimensions (L x W x H) mm | Body: 84 x 57mm (L x H), Coil size: 34 x 23mm (W x H) |
| Weight (g) | 100 |
| Shipping Weight | 0.12 kg |
| Shipping Dimensions | 10 × 8 × 5 cm |
What's in the box
- 1 x 12V Solenoid Water Air Valve Switch (Normally Closed) - 1/2 inch
Frequently Asked Questions
How does a normally closed valve behave?
What power supply do I need?
Which fluids can it handle?
What hose size fits the valve?
Does it work on a gravity fed tank?
How do I know which side is the inlet?
Overview
This 12V DC solenoid valve gives you electrical control over the flow of water, oil or air in a hose line. In its resting state the valve is closed, so nothing passes through. Apply 12V DC to the two coil terminals and the internal plunger lifts, opening the path between the 1/2 inch hose barbs. Remove power and the valve returns to closed. That behaviour makes it a natural fit for timers, float switches, relays and microcontroller-driven projects where flow should only occur on command.
Key Features
- Normally closed operation: flow is blocked until the coil is energised.
- 1/2 inch hose barbs: push a matching hose straight onto the inlet and outlet.
- 8W, 1A coil: runs from a 12VDC supply at roughly 1 amp.
- Wide pressure window: rated for 0.02 to 0.8MPa line pressure.
- Fluid flexibility: suitable for water, oil and air up to 100 degrees C.
- Compact body: 84 x 57mm with a 34 x 23mm coil, around 100g.
Specifications Explained
The 12VDC rating means the coil expects a 12 volt direct current supply and draws about 1A, so choose a power source and switching device that can carry that current comfortably. Power consumption is 8W. The pressure range of 0.02 to 0.8MPa tells you the valve needs a pressurised line to work correctly; it is not intended for gravity fed systems. The 100 degrees C maximum fluid temperature covers typical hot water and warm oil duties within that limit. Hose barbs suit 1/2 inch outer diameter hose, and the normally closed configuration means the safe state is shut, which is useful when power is lost. The coil is rated for intermittent energised operation rather than continuous duty, so plan your control logic with that in mind.
Compatibility and Requirements
You need a 12V DC supply capable of around 1A, plus a switch, relay or controller to energise the coil. Hoses must match the 1/2 inch outer diameter barbs. The valve must be installed in the correct flow direction: inside the body, the filter side marks the inlet. Installation angle can be arbitrary. Do not use it on unpressurised gravity fed systems.
Typical Uses
Robotic gardening and drip irrigation, automated water top-up, small pneumatic circuits, oil transfer lines and general DIY fluid control where a 12V trigger is available.
What's in the Box
One 12V solenoid water and air valve switch, normally closed, 1/2 inch.
Quick specs
- Item Type
- Normally Closed
- Voltage Rating (V)
- 12VDC
- Current Rating (A)
- 1
- Operating Voltage (VDC)
- 12
- Operation Mode
- Normally Closed
- Power Consumption (W)
- 8