Skip to main content

Worldwide Shipping · Secure Payments

AI Summary

An inline turbidity sensor covering 0-4000 NTU with dual 4-20 mA and RS485 output. Its 316 stainless steel, IP68 housing handles pressures to 3 bar and temperatures to 80 °C in continuous industrial monitoring.

Key Highlights

  • 0-4000 NTU range with 0.01% resolution
  • Dual output: adjustable 4-20 mA plus RS485 Modbus-RTU
  • 316 stainless steel body rated IP68 for submerged use
  • Measures temperature from 0 to 80 °C
  • Withstands pressure from 0 to 3 bar
  • Runs on 9-30 VDC, drawing 10 W or less

Ideal For

  • Water treatment plant instrument technicians
  • Industrial process and SCADA integrators
  • Pharmaceutical and chemical plant engineers
  • Power generation water system operators
  • Petroleum and food industry quality teams

Buying Tip

Confirm your controller accepts either a 4-20 mA loop or RS485 MODBUS-RTU before ordering, and check that line pressure stays within 0-3 bar and temperature within 0-80 °C.

Elecvora expert review

Our verdict

A solid inline turbidity sensor for industrial water monitoring, offering both analog and digital outputs in a sealed stainless steel body. It is a practical fit where a controller needs reliable NTU data over a long service life.

AI-assisted analysis based on the manufacturer's specifications. Not a hands-on lab test.

Pros

  • Dual 4-20 mA and RS485 outputs add integration flexibility
  • IP68 and 316 stainless steel suit wet, demanding sites
  • Wide 0-4000 NTU range covers clean and turbid water
  • Temperature measurement included up to 80 °C

Cons

  • Requires an external 9-30 VDC supply
  • No mounting hardware or cable details are specified
  • Pressure limited to 3 bar, so high-pressure lines need care

Best for

Industrial and municipal water turbidity monitoring with PLC or SCADA integration

Not ideal for

High-pressure lines above 3 bar or battery-only field deployments

Specifications

Model No. / NameFST100-ZD102
Measurement Range0.4000 NTU
Resolution0.01%
Withstand Voltage0 to 3 bar
Shell Material316 Stainless Steel
Power Consumption (W)≤10
Input Voltage (VDC)9~30, 12VDC recommended
Operating humidity<90%
Protection ClassIp68
Measuring Temperature (°C)0 to 80
Shipping Weight1.5 kg
Shipping Dimensions15 × 15 × 20 cm

What's in the box

  • 1 x FirstRate ST100-ZD102 Turbidity Sensor, Range 0-4000 NTU, 4-20 mA, RS485

Frequently Asked Questions

What turbidity range does this sensor measure?
It covers 0-4000 NTU with 0.01% resolution, so it can handle both low-turbidity and heavily loaded water.
What output signals are available?
The sensor provides an adjustable 4-20 mA current output and RS485 communication using MODBUS-RTU.
What power supply does it need?
It accepts 9-30 VDC, with 12 VDC recommended, and consumes 10 W or less.
Can it be submerged?
Yes. The housing is 316 stainless steel with an IP68 protection rating, suitable for submerged installation.
What are the temperature and pressure limits?
Measuring temperature is 0-80 °C and the withstand pressure is 0-3 bar.
What is included with the sensor?
The package contains 1 x FirstRate ST100-ZD102 Turbidity Sensor, Range 0-4000 NTU, 4-20 mA, RS485.

Overview

The FirstRate FST100-ZD102 is a turbidity sensor for continuous measurement in water and process lines. It spans 0-4000 NTU and reports through an adjustable 4-20 mA current loop and RS485 communication, giving integrators a choice of analog or digital data paths into a control system.

Its 316 stainless steel shell is rated IP68, so the sensor can remain submerged, and it operates across a measuring temperature of 0 to 80 °C at pressures from 0 to 3 bar. Power comes from a 9-30 VDC supply, with 12 VDC recommended.

Key Features

  • Wide turbidity coverage: 0-4000 NTU suits both low-turbidity clean water and heavier suspended solids.
  • Fine resolution: 0.01% resolution supports detailed trend monitoring.
  • Two signal outputs: adjustable 4-20 mA plus RS485 (MODBUS-RTU) for flexible integration.
  • Durable housing: 316 stainless steel construction with IP68 protection.
  • Temperature measurement: readings from 0 to 80 °C with 0.1 °C resolution.
  • Low power draw: 10 W or less from a 9-30 VDC input.

Specifications Explained

The 0-4000 NTU range defines how much suspended material the sensor can quantify before the signal saturates. The 0.01% resolution means small changes in turbidity remain visible in logged data, which helps when tracking slow drift.

The 4-20 mA output is a standard analog signal accepted by most PLCs and transmitters, while RS485 with MODBUS-RTU allows multiple devices on one bus and gives access to digital values. Choose whichever suits your controller.

IP68 and 316 stainless steel indicate the sensor is built for wet, corrosive-leaning environments, and the 0-3 bar pressure rating sets the line pressure limit. The 9-30 VDC input with 12 VDC recommended keeps wiring simple on common industrial supplies.

Compatibility and Requirements

The sensor needs a 9-30 VDC power source and a receiving device that accepts either a 4-20 mA loop or RS485 MODBUS-RTU. Ambient humidity should stay below 90%. Confirm your process temperature stays within 0-80 °C and pressure within 0-3 bar.

Typical Uses

  • Water treatment and distribution monitoring
  • Metallurgy and electric power plant water systems
  • Pharmaceutical and chemical process lines
  • Petroleum industry water quality checks
  • Food industry turbidity measurement

What's in the Box

1 x FirstRate ST100-ZD102 Turbidity Sensor, Range 0-4000 NTU, 4-20 mA, RS485.

Quick specs

Model No. / Name
FST100-ZD102
Measurement Range
0.4000 NTU
Resolution
0.01%
Withstand Voltage
0 to 3 bar
Shell Material
316 Stainless Steel
Power Consumption (W)
≤10
See all specifications