1 / 4 · Click to enlarge
AI Summary
An inline turbidity sensor covering 0-4000 NTU with dual 4-20 mA and RS485 output. Its 316 stainless steel, IP68 housing handles pressures to 3 bar and temperatures to 80 °C in continuous industrial monitoring.
Key Highlights
- 0-4000 NTU range with 0.01% resolution
- Dual output: adjustable 4-20 mA plus RS485 Modbus-RTU
- 316 stainless steel body rated IP68 for submerged use
- Measures temperature from 0 to 80 °C
- Withstands pressure from 0 to 3 bar
- Runs on 9-30 VDC, drawing 10 W or less
Ideal For
- Water treatment plant instrument technicians
- Industrial process and SCADA integrators
- Pharmaceutical and chemical plant engineers
- Power generation water system operators
- Petroleum and food industry quality teams
Buying Tip
Confirm your controller accepts either a 4-20 mA loop or RS485 MODBUS-RTU before ordering, and check that line pressure stays within 0-3 bar and temperature within 0-80 °C.
Elecvora expert review
Our verdict
A solid inline turbidity sensor for industrial water monitoring, offering both analog and digital outputs in a sealed stainless steel body. It is a practical fit where a controller needs reliable NTU data over a long service life.
AI-assisted analysis based on the manufacturer's specifications. Not a hands-on lab test.
Pros
- Dual 4-20 mA and RS485 outputs add integration flexibility
- IP68 and 316 stainless steel suit wet, demanding sites
- Wide 0-4000 NTU range covers clean and turbid water
- Temperature measurement included up to 80 °C
Cons
- Requires an external 9-30 VDC supply
- No mounting hardware or cable details are specified
- Pressure limited to 3 bar, so high-pressure lines need care
Best for
Industrial and municipal water turbidity monitoring with PLC or SCADA integration
Not ideal for
High-pressure lines above 3 bar or battery-only field deployments
Specifications
| Model No. / Name | FST100-ZD102 |
|---|---|
| Measurement Range | 0.4000 NTU |
| Resolution | 0.01% |
| Withstand Voltage | 0 to 3 bar |
| Shell Material | 316 Stainless Steel |
| Power Consumption (W) | ≤10 |
| Input Voltage (VDC) | 9~30, 12VDC recommended |
| Operating humidity | <90% |
| Protection Class | Ip68 |
| Measuring Temperature (°C) | 0 to 80 |
| Shipping Weight | 1.5 kg |
| Shipping Dimensions | 15 × 15 × 20 cm |
What's in the box
- 1 x FirstRate ST100-ZD102 Turbidity Sensor, Range 0-4000 NTU, 4-20 mA, RS485
Frequently Asked Questions
What turbidity range does this sensor measure?
What output signals are available?
What power supply does it need?
Can it be submerged?
What are the temperature and pressure limits?
What is included with the sensor?
Overview
The FirstRate FST100-ZD102 is a turbidity sensor for continuous measurement in water and process lines. It spans 0-4000 NTU and reports through an adjustable 4-20 mA current loop and RS485 communication, giving integrators a choice of analog or digital data paths into a control system.
Its 316 stainless steel shell is rated IP68, so the sensor can remain submerged, and it operates across a measuring temperature of 0 to 80 °C at pressures from 0 to 3 bar. Power comes from a 9-30 VDC supply, with 12 VDC recommended.
Key Features
- Wide turbidity coverage: 0-4000 NTU suits both low-turbidity clean water and heavier suspended solids.
- Fine resolution: 0.01% resolution supports detailed trend monitoring.
- Two signal outputs: adjustable 4-20 mA plus RS485 (MODBUS-RTU) for flexible integration.
- Durable housing: 316 stainless steel construction with IP68 protection.
- Temperature measurement: readings from 0 to 80 °C with 0.1 °C resolution.
- Low power draw: 10 W or less from a 9-30 VDC input.
Specifications Explained
The 0-4000 NTU range defines how much suspended material the sensor can quantify before the signal saturates. The 0.01% resolution means small changes in turbidity remain visible in logged data, which helps when tracking slow drift.
The 4-20 mA output is a standard analog signal accepted by most PLCs and transmitters, while RS485 with MODBUS-RTU allows multiple devices on one bus and gives access to digital values. Choose whichever suits your controller.
IP68 and 316 stainless steel indicate the sensor is built for wet, corrosive-leaning environments, and the 0-3 bar pressure rating sets the line pressure limit. The 9-30 VDC input with 12 VDC recommended keeps wiring simple on common industrial supplies.
Compatibility and Requirements
The sensor needs a 9-30 VDC power source and a receiving device that accepts either a 4-20 mA loop or RS485 MODBUS-RTU. Ambient humidity should stay below 90%. Confirm your process temperature stays within 0-80 °C and pressure within 0-3 bar.
Typical Uses
- Water treatment and distribution monitoring
- Metallurgy and electric power plant water systems
- Pharmaceutical and chemical process lines
- Petroleum industry water quality checks
- Food industry turbidity measurement
What's in the Box
1 x FirstRate ST100-ZD102 Turbidity Sensor, Range 0-4000 NTU, 4-20 mA, RS485.
Quick specs
- Model No. / Name
- FST100-ZD102
- Measurement Range
- 0.4000 NTU
- Resolution
- 0.01%
- Withstand Voltage
- 0 to 3 bar
- Shell Material
- 316 Stainless Steel
- Power Consumption (W)
- ≤10