1 / 5 · Click to enlarge
AI Summary
A portable ATC refractometer for measuring protein concentration and urine specific gravity in liquid samples. It provides quick, accurate readings with automatic temperature compensation and a clear high-definition eyepiece.
Key Highlights
- Measures protein (SP) 0–12 g/dL and urine specific gravity (U.G) 1.000–1.050 ND
- Automatic temperature compensation for consistent readings between 10°C and 30°C
- Aluminum body with soft silicone handle for durability and comfortable grip
- High-definition eyepiece for precise, easy-to-read results
- Lightweight and compact design for portability and field use
- Simple calibration with included adjustment bolt
Ideal For
- Medical and veterinary clinics for quick proteinuria screening
- Laboratory technicians measuring protein concentration
- Students and educators demonstrating refractive index
- Field researchers needing portable concentration measurement
- Quality control staff in food and beverage production
Buying Tip
Calibrate with distilled water before first use and after major temperature changes to ensure accurate readings.
Elecvora expert review
Our verdict
A practical, no-frills refractometer that delivers accurate protein and urine specific gravity readings with the convenience of automatic temperature compensation. Its sturdy aluminum build and clear optics make it a reliable tool for routine screening.
AI-assisted analysis based on the manufacturer's specifications. Not a hands-on lab test.
Pros
- Dual scales cover both protein and urine specific gravity
- ATC ensures stable readings across 10–30°C
- Clear, high-definition eyepiece for easy reading
- Lightweight and portable with comfortable grip
- Battery-free operation
Cons
- Requires manual calibration with distilled water
- Not suitable for highly viscous or opaque samples
- Calibration solution and accessories not included
Best for
Routine protein and urine concentration screening in clinics, labs, and field settings
Not ideal for
High-precision research or samples outside the 10–30°C range
Specifications
| Model No. / Name | Refractometer |
|---|---|
| Accuracy | SP:0.2g/dL, U.G:0.0005ND |
| Structure | Refractive prism + cover + calibration bolt + eyepiece + optical system piping |
| Operating Temperature (°C) | 10~30degrees |
| Shipping Weight | 0.24 kg |
| Shipping Dimensions | 20 × 8 × 6 cm |
What's in the box
- 1 x Medical Refractometer ATC Protein Refractometer Concentration Meter
Frequently Asked Questions
What is the difference between the SP and U.G scales?
Does this refractometer require batteries?
How often should I calibrate?
Can I use this for other liquids like juice or milk?
What is included in the package?
How should I clean the refractometer?
Overview
The Generic Medical Refractometer ATC is a handheld optical instrument designed to measure the concentration of protein and the specific gravity of urine in liquid samples. It operates on the principle that dissolved substances change the refractive index of a solution. By placing a small sample on the prism and looking through the eyepiece, users can read the concentration directly from the scale. Automatic temperature compensation (ATC) minimises the effect of sample temperature variations, ensuring reliable results without waiting for samples to reach a specific temperature.
Key Features
- Dual scales: Protein (SP) range 0–12 g/dL with 0.2 g/dL division; urine specific gravity (U.G) range 1.000–1.050 ND with 0.0005 ND division.
- Automatic temperature compensation: Maintains accuracy when operating between 10°C and 30°C.
- Durable construction: Aluminum body resists wear, while the soft silicone handle improves grip.
- High-definition optics: The eyepiece provides a wide field of view for clear scale reading.
- Portable design: Compact and lightweight, making it easy to carry for field or clinical use.
- Easy calibration: A calibration bolt allows quick adjustment using distilled water.
Specifications Explained
Accuracy: The protein scale reads to 0.2 g/dL, and the urine specific gravity scale reads to 0.0005 ND. These fine divisions allow precise assessment of sample concentration.
Measuring ranges: The SP scale covers 0–12 g/dL, suitable for typical protein concentration measurements. The U.G scale covers 1.000–1.050 ND, covering the normal and elevated ranges of urine specific gravity.
Operating temperature: Designed for use in ambient temperatures from 10°C to 30°C. ATC compensates for sample temperature within this range, reducing reading errors.
Structure: The optical system includes a refractive prism, cover plate, calibration bolt, eyepiece, and internal piping, all housed in a durable aluminum body.
Compatibility and Requirements
This refractometer requires only a small liquid sample (typically a few drops) and a source of distilled water for calibration. It does not require batteries or external power. It is suitable for measuring aqueous solutions; highly viscous or opaque samples may not be appropriate. The instrument should be cleaned and dried after each use to maintain optical clarity.
Typical Uses
- Clinical and veterinary settings for rapid proteinuria screening or urine concentration assessment.
- Laboratory and educational environments for demonstrating refractive index principles.
- Quality control in food and beverage production where protein content is monitored.
- Field work where a portable, battery-free measurement tool is beneficial.
What's in the Box
Package includes: 1 x Medical Refractometer ATC Protein Refractometer Concentration Meter. (Note: Calibration solution, pipette, and carrying case are not included unless specified.)
Quick specs
- Model No. / Name
- Refractometer
- Accuracy
- SP:0.2g/dL, U.G:0.0005ND
- Structure
- Refractive prism + cover + calibration bolt + eyepiece + optical system piping
- Operating Temperature (°C)
- 10~30degrees
- Shipping Weight
- 0.24 kg
- Shipping Dimensions
- 20 × 8 × 6 cm