Skip to main content

Worldwide Shipping · Secure Payments

AI Summary

The PLANTOWER PMSA003-C is a UART-enabled laser particle sensor that measures PM2.5 concentrations from 0.3 to 10 µm. It provides real-time, accurate data for air quality monitoring projects.

Key Highlights

  • Detects particles from 0.3 to 10 µm
  • UART digital output for easy integration
  • Operates on 4.5 to 5.5 V supply
  • Maximum range of at least 1000 µg/m³
  • Six-sided shielding for anti-interference
  • Real-time response with high sensitivity

Ideal For

  • Makers building DIY air quality monitors
  • IoT developers integrating environmental sensing
  • HVAC technicians monitoring particulate levels
  • Researchers collecting air pollution data
  • Smart home enthusiasts adding automation triggers

Buying Tip

Remember to order a compatible cable or connector separately, as the sensor does not include wiring.

Elecvora expert review

Our verdict

The PLANTOWER PMSA003-C is a solid choice for adding PM2.5 sensing to your projects, offering reliable UART output and a wide detection range. Its robust shielding and real-time response make it suitable for both hobbyist and professional applications.

AI-assisted analysis based on the manufacturer's specifications. Not a hands-on lab test.

Pros

  • Wide particle detection range (0.3–10 µm)
  • High maximum concentration range (≥1000 µg/m³)
  • UART interface simplifies integration
  • Anti-interference shielding for stable readings

Cons

  • Cable not included, requires separate purchase
  • Requires 5 V supply, not 3.3 V compatible

Best for

Air quality monitoring projects requiring accurate PM2.5 data

Not ideal for

Applications needing battery-powered operation without a 5 V source

Specifications

Power Supply Voltage (V)4.5 to 5.5 v
Maximum range(M)≥1000 μ g/m³
Shipping Weight0.045 kg
Shipping Dimensions15 × 10 × 2 cm

What's in the box

  • 1 x PLANTOWER PMSA003-C Gas Sensor UART

Frequently Asked Questions

What is the detection range of this sensor?
The PMSA003-C detects particles from 0.3 to 10 µm, covering PM2.5 and PM10 sizes.
What interface does the sensor use?
It uses a UART digital interface for data output, compatible with most microcontrollers.
What power supply does it require?
The sensor operates on a voltage between 4.5 and 5.5 V, typically 5 V.
Is a cable included?
No, the product does not include a cable. You will need to provide your own wiring.
Can I use this sensor outdoors?
Yes, it can be used outdoors if protected from direct moisture and dust, but ensure the enclosure allows airflow.
How do I maintain the sensor?
Avoid exposing the sensor to excessive dust or moisture; periodic cleaning of the enclosure's air inlet may be necessary.

Overview

The PLANTOWER PMSA003-C is a digital laser particle concentration sensor designed to measure suspended particulate matter in the air. It outputs particle concentration data through a UART interface, making it easy to integrate into a wide range of electronic projects. Whether you are developing an air quality monitor, a smart home device, or an environmental data logger, this sensor provides accurate and timely information about PM2.5 levels.

Key Features

  • High Sensitivity: Detects particles as small as 0.3 µm, covering the typical PM2.5 range.
  • Real-Time Response: Delivers quick data output for dynamic monitoring applications.
  • Anti-Interference Design: Patent six-sided shielding reduces electromagnetic interference for stable readings.
  • Customizable Airflow Direction: Adaptable to various enclosure designs and airflow paths.
  • Zero False Alarm Rate: Ensures accurate readings without spurious triggers.

Specifications Explained

Power Supply Voltage (4.5 to 5.5 V): The sensor operates on a standard 5 V supply, compatible with most microcontrollers and development boards. Ensure your power source can provide a stable voltage within this range.

Maximum Range (≥1000 µg/m³): The sensor can measure particle concentrations up to at least 1000 micrograms per cubic meter, making it suitable for heavily polluted environments as well as typical indoor air.

Particle Detection Range (0.3 to 10 µm): This range covers fine particles (PM2.5) and coarse particles (PM10), allowing the sensor to provide comprehensive particulate data.

UART Interface: The digital UART output simplifies connection to microcontrollers, enabling straightforward data acquisition without complex analog circuitry.

Compatibility and Requirements

The PMSA003-C requires a 5 V power supply and a UART-capable host device, such as an Arduino, Raspberry Pi, or other microcontroller. Note that a cable is not included, so you will need to provide your own wiring. The sensor is designed for integration into custom enclosures or instruments.

Typical Uses

  • Air quality monitoring stations
  • Smart home environmental sensors
  • HVAC system feedback
  • Portable pollution trackers
  • Educational and research projects

What's in the Box

1 x PLANTOWER PMSA003-C Gas Sensor UART

Quick specs

Power Supply Voltage (V)
4.5 to 5.5 v
Maximum range(M)
≥1000 μ g/m³
Shipping Weight
0.045 kg
Shipping Dimensions
15 × 10 × 2 cm
See all specifications