Skip to main content

Worldwide Shipping · Secure Payments

AI Summary

A compact laser particle sensor that measures 0.3–10 µm particles and reports PM2.5 concentration over UART. It runs on a 4.5–5.5 V supply and responds in under one second, making live air quality data easy to integrate.

Key Highlights

  • Laser particle detection across the 0.3 to 10 µm size range
  • PM2.5 measurement from 0 to 500 µg/m³, maximum range ≥1000 µg/m³
  • Digital UART output for direct connection to microcontrollers
  • Single response time under 1 second; total response ≤10 seconds
  • Six-sided shielding reduces interference in dense enclosures
  • Flexible air inlet and outlet orientation for varied builds

Ideal For

  • Makers building indoor PM2.5 air quality monitors
  • Product engineers integrating particle sensing into instruments
  • Air purifier and ventilation designers needing live particle feedback
  • Students and researchers logging particulate data
  • Embedded developers working with UART sensor modules

Buying Tip

Confirm your host board has a free UART port and a stable 5 V rail before ordering, since the sensor needs both to deliver readings.

Elecvora expert review

Our verdict

A practical particle sensing module for anyone who needs PM2.5 data over a simple serial link. The wide particle range, fast response and shielded design make it a sensible building block for air quality projects.

AI-assisted analysis based on the manufacturer's specifications. Not a hands-on lab test.

Pros

  • Detects particles from 0.3 to 10 µm with stated counting efficiency
  • Fast response under one second for single readings
  • UART output simplifies integration with microcontrollers
  • Six-sided shielding helps in electrically noisy builds
  • Flexible inlet and outlet orientation aids enclosure design

Cons

  • Needs a host board and wiring; not a standalone instrument
  • No cable or enclosure included
  • Requires a supply kept within 4.5 to 5.5 V

Best for

Makers and engineers building UART-based PM2.5 monitoring devices

Not ideal for

Users wanting a plug-and-play air quality meter with a display

Specifications

Item TypeGas Sensor
Power Supply Voltage (V)4.5 to 5.5 v
Maximum range(M)≥1000 μ g/m³
Shipping Weight0.045 kg
Shipping Dimensions15 × 10 × 2 cm

What's in the box

  • 1 x PLANTOWER PMSA003-A gas sensor with UART output

Frequently Asked Questions

What interface does the PMSA003-A use?
It outputs particle concentration data over a digital UART interface, so it connects to a host board's serial port.
What voltage does the sensor need?
The power supply voltage must be between 4.5 and 5.5 V. Stay within this range for reliable operation.
What particle sizes can it detect?
It covers particles from 0.3 to 10 µm, with 50% counting efficiency at 0.3 µm and 98% at 0.5 µm and above.
What is the PM2.5 measurement range?
The effective range is 0 to 500 µg/m³, and the maximum range is at least 1000 µg/m³.
What is included with the sensor?
The package contains one PLANTOWER PMSA003-A gas sensor with UART output. Cables, host boards and enclosures are not included.
How should I care for the sensor?
Keep the airflow inlet and outlet unobstructed and mount the module securely so dust buildup and vibration do not affect readings.

Overview

The PLANTOWER PMSA003-A is a digital particle concentration sensor built around laser detection. It counts suspended particles in the air and reports the resulting concentration through a UART interface, so a host board can read air quality data without extra analogue circuitry. The module is aimed at makers, developers and product teams who need a compact sensing element inside an air quality monitor, environmental instrument or air treatment device.

Key Features

  • Wide particle coverage: detects particles from 0.3 µm up to 10 µm, with 50% counting efficiency at 0.3 µm and 98% at 0.5 µm and above.
  • PM2.5 measurement: effective range of 0 to 500 µg/m³, with a maximum range of at least 1000 µg/m³.
  • Fast updates: single response time under 1 second and total response time of 10 seconds or less.
  • Digital output: UART interface delivers concentration readings directly to a microcontroller or host system.
  • Anti-interference build: six-sided shielding supports stable operation in electrically noisy environments.
  • Flexible airflow: air inlet and outlet directions can be adapted to suit different installation layouts.

Specifications Explained

Particle size range

The 0.3 to 10 µm span covers fine particulate matter, including the PM2.5 fraction that most air quality applications focus on. The 0.3 µm lower limit means the sensor can register very small particles, while the counting efficiency figures describe how reliably it detects them at each size.

Measurement range

The effective PM2.5 range is 0 to 500 µg/m³, which suits typical indoor and outdoor monitoring scenarios. The maximum range of at least 1000 µg/m³ indicates headroom beyond the effective band for heavier particle loading.

Power supply

The module accepts 4.5 to 5.5 V, matching common 5 V logic rails and USB-derived supplies. Keep the supply within this window for consistent readings.

Response time

A single response time below one second and a total response of 10 seconds or less mean the output follows changes in particle concentration closely, which matters for live displays and control loops.

Compatibility and Requirements

The sensor communicates over UART, so the host device must provide a compatible serial interface. Power must be supplied within the 4.5 to 5.5 V range. Because the module is a sensing component rather than a finished instrument, it requires a host board, wiring and an enclosure or mounting arrangement to be useful. Air inlet and outlet orientation should be planned so that ambient air can reach the sensing chamber.

Typical Uses

  • Indoor air quality monitors and displays
  • Environmental monitoring instruments
  • Air purifiers and ventilation equipment needing particle feedback
  • Educational and research projects on particulate matter
  • Embedded prototypes that log PM2.5 data

What's in the Box

One PLANTOWER PMSA003-A gas sensor with UART output. Host boards, cables and enclosures are not included.

Quick specs

Item Type
Gas Sensor
Power Supply Voltage (V)
4.5 to 5.5 v
Maximum range(M)
≥1000 μ g/m³
Shipping Weight
0.045 kg
Shipping Dimensions
15 × 10 × 2 cm