Skip to main content

Worldwide Shipping · Secure Payments

AI Summary

A Class A PT100 RTD probe with a 4 x 30 mm stainless steel body and 1.5 m shielded FEP cable for measuring -50°C to +200°C in air or liquids. Its 4-wire design and fast water response make repeatable readings easier to achieve.

Key Highlights

  • Class A PT100 platinum element with 100 ohms nominal resistance at 0°C
  • 4 x 30 mm SUS304 stainless steel probe for air and liquid contact
  • 1.5 m FEP cable with stainless steel shielding and 4-wire wiring
  • Measures from -50°C to +200°C with fast response in water
  • Handles vibration to 40g and shock to 100g in demanding settings
  • Insulation resistance above 100 MΩ at 20°C for stable signals

Ideal For

  • Automation engineers monitoring process lines
  • Laboratory technicians measuring baths and samples
  • HVAC and facilities teams checking duct temperatures
  • Makers building temperature logging systems
  • Maintenance crews testing industrial equipment

Buying Tip

Confirm your reader or transmitter accepts a 4-wire PT100 input and can supply a measuring current between 0.3 and 1.0 mA before ordering.

Elecvora expert review

Our verdict

A compact, well-shielded Class A PT100 probe that covers a wide temperature span and responds quickly in liquids. It is a sensible choice for anyone who already has a compatible 4-wire RTD reader and needs dependable readings.

AI-assisted analysis based on the manufacturer's specifications. Not a hands-on lab test.

Pros

  • Class A tolerance for closer readings
  • Fast response in water
  • Shielded FEP cable for wet or noisy settings
  • Wide -50°C to +200°C range
  • Small 4 x 30 mm probe fits tight spaces

Cons

  • Requires a separate RTD reader or transmitter
  • No connector or terminal block included
  • 4-wire wiring needs a compatible input

Best for

Engineers and technicians with a 4-wire PT100 reader who need a compact, shielded probe

Not ideal for

Users wanting a self-contained thermometer or a plug-and-play display unit

Specifications

Shipping Weight0.056 kg
Shipping Dimensions11 × 11 × 3 cm

What's in the box

  • 1 x PT100 A-class Temperature Sensor 4*30mm 1.5M

Frequently Asked Questions

Does this sensor work without a separate reader?
No. It is a passive PT100 resistance element, so you need an RTD reader, transmitter, or controller to turn the resistance change into a temperature reading.
Can I use it in water or other liquids?
Yes. The SUS304 stainless steel probe is designed for liquid contact, and response time in water is t0.5 = 0.06 s and t0.9 = 0.20 s.
What temperature range does it cover?
The stated range is -50°C to +200°C. Keep both the probe and cable within that range.
How many wires does the cable have?
It is a 4-wire configuration, which helps reduce lead-resistance error in the measurement circuit.
What is included in the package?
The package contains one PT100 A-class temperature sensor with a 4 x 30 mm probe and a 1.5 m cable.
How should I care for the probe and cable?
Avoid sharp bends, pulling on the cable, and temperatures outside the stated range. Check the FEP sheath for damage before use in wet areas.

Overview

The Generic PT100 A-Class Temperature Sensor is a resistance temperature detector built around a platinum element with a nominal 100 ohm resistance at 0°C. It follows the DIN EN 60751 Class A tolerance, which keeps readings close to the true temperature across the working range. The element is housed in a 4 mm diameter, 30 mm long SUS304 stainless steel probe, giving it a slim profile for ducts, pipes, baths, and small vessels.

A 1.5 m cable connects the probe to your reading instrument. The cable uses FEP insulation, a stainless steel shield, and an FEP outer sheath, and it is wired in a 4-wire configuration to help cancel lead resistance in the measurement circuit.

Key Features

  • Platinum PT100 sensing element with Class A accuracy
  • SUS304 stainless steel probe, 4 mm x 30 mm
  • FEP-insulated, shielded cable with 1.5 m length
  • 4-wire connection for reduced lead-resistance error
  • Temperature range of -50°C to +200°C
  • Vibration resistance to 40g and shock resistance to 100g

Specifications Explained

Accuracy and element

Class A (F0.15) describes the tolerance band of the platinum element, and the 3850 ppm/K temperature coefficient is the standard platinum curve. Together these matter if you compare readings across sensors or log data over time.

Probe and cable

The 4 mm x 30 mm stainless steel body responds quickly because of its small mass. The cable's FEP insulation and stainless steel shield protect the signal in wet, oily, or electrically noisy areas.

Response and limits

Response time is t0.5 = 0.06 s and t0.9 = 0.20 s in water, while in air it is t0.5 = 3.0 s and t0.9 = 13.0 s. Insulation resistance is above 100 MΩ at 20°C, and self-heating is 0.4 K/mW at 0°C, so keep measuring current within the stated 0.3–1.0 mA range.

Compatibility and Requirements

This is a passive resistive sensor, so it needs a separate RTD reader, transmitter, or controller designed for 4-wire PT100 inputs. No reading electronics are included. Use it only within -50°C to +200°C.

Typical Uses

  • Laboratory baths and sample temperature checks
  • Industrial process and pipeline monitoring
  • HVAC duct and air temperature measurement
  • Automation and control panel sensing
  • Equipment testing and calibration reference work

What's in the Box

1 x PT100 A-class Temperature Sensor 4*30mm 1.5M

Quick specs

Shipping Weight
0.056 kg
Shipping Dimensions
11 × 11 × 3 cm
See all specifications