
1 / 3 · Click to enlarge
AI Summary
A compact single phase energy meter that reads active consumption on 230VAC circuits from 5 to 32A and clips onto standard 35mm DIN rail. Its clear LCD and slim 78.5 x 36.5mm housing make circuit-level energy monitoring simple to install.
Key Highlights
- Measures active energy on 230VAC single phase circuits
- Rated current range from 5A up to 32A
- Clear LCD for straightforward data display
- Fits standard 35mm DIN rail for quick installation
- Slim 78.5 x 36.5mm body weighs only 113g
- Operates from -25C to 55C at up to 95%RH
Ideal For
- Electricians adding circuit-level sub-metering
- Homeowners tracking energy use in a rental unit
- Workshop owners monitoring tool and equipment consumption
- Facility teams checking loads in panel boards
- Makers building energy-aware equipment cabinets
Buying Tip
Check that your circuit is single phase 230VAC at 50Hz and that the expected load stays within the 5 to 32A range before ordering.
Elecvora expert review
Our verdict
A neat, no-fuss single phase meter that covers a useful 5 to 32A span and installs on standard DIN rail. It is a sensible pick for straightforward circuit-level energy monitoring where a compact footprint matters.
AI-assisted analysis based on the manufacturer's specifications. Not a hands-on lab test.
Pros
- Wide 5 to 32A rated current range
- Compact 78.5 x 36.5mm housing and light 113g weight
- Standard 35mm DIN rail mounting
- Clear LCD data display
- Broad -25C to 55C operating range
Cons
- No display backlight, so readings need decent ambient light
- Rated for 230VAC 50Hz single phase only
- No package details beyond the meter and seal caps
Best for
Circuit-level energy monitoring in homes, workshops and small commercial boards
Not ideal for
Three phase systems or loads outside the 5 to 32A range
Specifications
| Voltage Rating | 230VAC |
|---|---|
| Rated Current (A) | 5 to 32 |
| Model No. / Name | DDS528 |
| LCD display | Data display |
| Display Backlight | No |
| Mounting Style | 35mm DIN rail |
| Operating Temperature (°C) | -25℃~55℃ |
| Opt. Relative Humidity(RH) | ≤95%RH |
| Dimensional Accuracy (mm) | 78.5x36.5mm |
| Weight (g) | 113g |
| Shipping Weight | 0.131 kg |
| Shipping Dimensions | 9 × 7 × 4 cm |
What's in the box
- 1 x DDS528L Energy Meter
- 4 x Seal Cap
Frequently Asked Questions
What voltage does this meter work with?
What current range can it measure?
How is the meter mounted?
Does the LCD have a backlight?
What comes in the box?
What are the operating conditions?
Overview
The DDS528L is a single phase electronic energy meter built to measure active energy consumption on 230VAC circuits. It covers a rated current range of 5 to 32A at 50Hz, so it suits a wide variety of small and medium loads rather than one fixed rating. Readings appear on an integrated LCD, giving you a direct view of consumption without extra equipment.
Mounting is handled by a 35mm DIN rail clip, which is the common standard in distribution boards and equipment cabinets. The housing measures just 78.5 x 36.5mm and weighs 113g, so it takes up minimal rail space and is easy to fit alongside breakers and other modules.
Key Features
- Single phase active energy metering for 230VAC circuits
- 5 to 32A rated current range covers a broad span of loads
- LCD data display for clear on-device readings
- 35mm DIN rail mounting for fast, tool-friendly installation
- Compact 78.5 x 36.5mm footprint and 113g weight
- Wide operating window from -25C to 55C and up to 95%RH
Specifications Explained
Voltage and frequency: The meter is rated for 230VAC at 50Hz, matching common single phase supplies. Confirm your circuit matches before wiring.
Current range: The 5 to 32A rating means the meter is intended for circuits operating within that band. Loads outside this range are not covered by the stated rating.
Display: The LCD presents data readings directly on the unit. There is no backlight, so readings are easiest to take in normal ambient light.
Mounting: The 35mm DIN rail clip is the standard profile used in most consumer units and panel boards, which keeps installation familiar for electricians.
Environmental limits: Operation from -25C to 55C with relative humidity up to 95%RH covers most indoor installation points, from cool utility areas to warmer equipment rooms.
Compatibility and Requirements
This meter is designed for single phase 230VAC systems at 50Hz with loads between 5 and 32A. It requires a 35mm DIN rail for mounting. No other accessories are specified in the product data, so plan wiring and enclosure space around your own installation.
Typical Uses
- Sub-metering a circuit in a home or rental property
- Tracking consumption of workshop tools and equipment
- Monitoring office or small commercial circuits
- Energy checks inside equipment cabinets and panel boards
What's in the Box
- 1 x DDS528L Energy Meter
- 4 x Seal Cap
Quick specs
- Voltage Rating
- 230VAC
- Rated Current (A)
- 5 to 32
- Model No. / Name
- DDS528
- LCD display
- Data display
- Display Backlight
- No
- Mounting Style
- 35mm DIN rail













