At a glance
Made by FY6900, this tools, industrial & scientific is a good fit for DIY builders and repair work. Main specs: model FY6900-100M; sine 0~100MHz; square 0~25MHz. Check that your power source supplies 1Vpp~20Vpp before connecting it.
Key Highlights
- Model: FY6900-100M
- Sine: 0~100MHz
- Square: 0~25MHz
Ideal For
- Repairs around the home
- Electronics bench work
- Workshop jobs
Buying Tip
Compare the pin layout and operating voltage with your circuit, and order a spare or two: small parts are easy to damage while soldering.
Specifications
| Model | FY6900-100M |
|---|---|
| Sine | 0~100MHz |
| Square | 0~25MHz |
| Ramp, Triangle | 0~10MHz |
| Pulse | 0~10MHz |
| TTL/CMOS | 0~10MHz |
| Arbitrary Waveform | 0~10MHz |
| Minimum Pulse Width | 20ns(All models of pulse wave minimum width can reach 20ns) |
| Package Weight | Approx. 1065g / 37.51oz(Main engine, accessories and packing materials) |
| Min. Resolution on all frequency range | 1μHz (Min. resolution can reach 1μHz on all frequency range to ensure adjusting accuracy under high frequency. For example, it can output 10.000000000001MHz signal). |
| Accuracy | ±20ppm |
| Stability | ±1ppm/ 3hours |
| Waveforms | Sine, Square, Rectangle (Duty Cycle adjustable), Pulse (Pulse width and cycle time can be set accurately), Triangle/Ramp, Sawtooth Wave, CMOS, Four channels TTL, DC, Half wave, Full wave, Positive Step, Inverse Step, Positive Exponent, Inverse Exponent, Lorenz Pulse, Multitone, Noise, ECG, Trapezoidal Pulse, Sinc Pulse, Narrow Pulse, Gauss White Noise, AM, FM, and other 64 sets customer-defined waveform. |
| Non-Volatile Storage | Can store 64 user-defined arbitrary waveforms, (8K 14bits) * 64 |
| Waveform Length | 8192 points * 14bits |
| Sampling Rate | 250MSa/s |
| Vertical Resolution | 14 bits |
| Sine | Harmonic Suppression |
| Total Harmonic Distortion | <0.5% (20Hz~20kHz,0dBm) |
| Rectangle | Rise/Fall Time |
| Overshoot | ≤5% |
| Duty Cycle | 0.01%~99.99% (Resolution 0.01%) |
| Sawtooth Wave | Linearity |
| Amplitude(VPP) | Frequency≤5MHz: 1mVpp~24Vpp;5MHz<Frequency≤10MHz: 1mVpp~20Vpp;10MHz<Frequency≤20MHz: 1mVpp~10Vpp;Frequency>20MHz: 1mVpp~5Vpp; |
| Resolution | 1mV |
| Amplitude Stability | ±0.5%/ 5 Hours |
| Amplitude flatness | ±2.5%(<10MHz);±5%(>10MHz) |
| Impedance | 50Ω±10%(Typical) |
| Protection | All channels can work more than 60 seconds when the load is short-circuited. |
| Offsets Range | Frequency≤20MHz: ±12V; Frequency>20MHz: ±2.5V; |
| Offsets Resolution | 1mV |
| Phase range | 0~359.99° |
| Phase resolution | 0.01° |
| TTL Level Amplitude | >3Vpp |
| Fan-out | >8 TTL LOAD |
| Rise/Fall Time | ≤10ns |
| Low Electric Level | <0.3V |
| High Electric Level | 1V~12V |
| Rise/Fall Time | ≤18ns |
| Function | Frequency, Period, Positive/Negative Pulse Width, Duty Cycle |
| Input Voltage Range | 1Vpp~20Vpp |
| Frequency Meter | Resolution |
| Range | 0.01Hz~100MHz |
| Sensitivity | Gate Time 3 grades (1S, 10S, 100S) adjustable |
| Counter | Range |
| Coupling | DC, AC |
| Working Mode | Manual |
| Period | Measurement Range |
| Pulse Width | Measurement Range |
| Resolution | 5ns |
| Duty Cycle | Range (Display) |
| Carrier Waveform | Sine, Square, Ramp, Arbitrary (except DC) |
| Sweep Type | Linear or Logarithm |
| Sweep Direction | Up, Down and roundtrip sweep directions |
| Sweep Objects | Frequency, Amplitude, Offsets, Duty Cycle |
| Sweep Time | 0.01S~999.99S/Step |
| Setting range | Starting position and Finishing position can be set arbitrarily. |
| Sweep Range | Decided by Parameters setting. |
| Modulation signal range to input | 0~5V |
| VCO signal frequency range | 0-2000Hz |
| VCO control object | voltage controlling frequency (VCF), voltage controlling amplitude, voltage controlling offsets, voltage controlling duty cycle. |
| VCO special function | Can Amplitude Modulate (AM) or Frequency Modulate (FM) by external analog signal. |
| Modulation Type | AM, FM, PM, ASK, FSK, PSK |
| Carrier Waveform | Sine, Square, Triangle, Ramp, Arbitrary waveform (Except DC) |
| Source | Internal (CH2) / External (VCO IN Port) |
| Modulating Waveform | Sine, Square, Triangle, Ramp, Arbitrary waveform |
| Depth | 0% to 120% |
| Modulating Frequency | Internal : 1μHz~1MHz; External: 1μHz~2KHz; |
| Source | Internal (CH2) / External (VCO IN Port) |
| Modulating Waveform | Sine, Square, Triangle, Ramp, Arbitrary waveform |
| Modulating Frequency | Internal : 1μHz~1MHz; External: 1μHz~2KHz; |
| Source | Internal (CH2) / External (VCO IN Port) |
| Modulating Waveform | Sine, Square, Triangle, Ramp, Arbitrary waveform |
| Phase Deviation | 0° to 360° |
| Modulating Frequency | Internal : 1μHz~1MHz; External: 1μHz~2KHz; |
| Source | Internal (CH2), External (ASK IN Port), Manual |
| Modulating Waveform | Square with 50% duty cycle. |
| Key Frequency | 1μHz~10MHz |
| Source | Internal (CH2), External (FSK IN Port), Manual |
| Modulating Waveform | Square with 50% duty cycle. |
| Key Frequency | 1μHz~10MHz |
| Source | Internal (CH2), External (PSK IN Port), Manual |
| Modulating Waveform | Square with 50% duty cycle. |
| Key Frequency | 1μHz~10MHz |
| Carrier Waveform | Sine, Square, Ramp, Arbitrary (except DC) |
| Burst Count | 1~1048575 |
| Trigger Source | Manual, Internal, External (AC/DC) |
| Display | Type |
| Save & Load | Amount |
| Position | 01 to 20 (01 for start default value) |
| Interface | Type |
| Protocol | Command line mode, providing communication protocols. |
| Communicating Speed | 9600bps (Industrial standard) |
| Power | Voltage Range |
| Technic | SMD, LSI, Reliable |
| Buzzer | Can be turned on/off by setting. |
| Operation | Buttons and knob continuously. |
| Environment | Temp.: 0~40℃, Humidity: ﹤80% |
| Size | Approx. 210mm * 195mm * 75mm / 8.27 * 7.68 * 2.96 (L * W * H) |
| Weight | Approx. 611g / 21.56oz |
| Package Size | Approx. 27cm * 21cm * 9.5cm / 10.63 * 8.27 * 3.75 (L * W * H) |
| Model number | FY6900-100M |
Overview
The FY6900 100MHz Signal Generator High Precision Digital DDS Dual-channel Function Signal/Arbitrary Waveform Generator, made by FY6900, is listed in our tools, industrial & scientific range and suits DIY builders and repair work. The notes below explain the main specifications and what to check before you order.
Specifications explained
- Model: FY6900-100M
- Sine: 0~100MHz (make sure the rest of your system works at this frequency)
- Square: 0~25MHz (make sure the rest of your system works at this frequency)
- Ramp, Triangle: 0~10MHz (your supply must deliver at least this much current)
- Pulse: 0~10MHz (make sure the rest of your system works at this frequency)
- TTL/CMOS: 0~10MHz (make sure the rest of your system works at this frequency)
- Arbitrary Waveform: 0~10MHz (make sure the rest of your system works at this frequency)
- Minimum Pulse Width: 20ns(All models of pulse wave minimum width can reach 20ns) (measure your mounting space before ordering)
Before you order
Compare the specifications with your project or device, and check delivery times and return terms for your country in our help centre. Questions about this item? Email [email protected] with the product code.
Features:
- Adopt the Direct Digital Synthesizer (DDS) technology and provide stable, precise, pure and low distortion signals.
- 2.4 inch TFT color LCD with 320*240 resolution, simultaneously display parameters and graphics of CH1 and CH2.
- Adopt MagicPulse Technology, Low Jitter(RMS)<200ps.
- The instrument uses 14-bit high-speed D/A converter chip (5Vpp output quantization error is less than 1mV), 250MSa/s sample rate, 14bits vertical resolution.
- Can output up to 99 groups of functions / arbitrary waveform, contains 35 groups of preset waveforms and 64 groups of user-defined waveforms. Preset waveforms: Sine, Square (Duty Cycle adjustable), Pulse (Pulse width and cycle time can be set accurately), Triangle/Ramp, CMOS(0~12V), Four channels TTL, Exponential Rise, Exponential Fall, Noise, ECG, DC etc.
- Enable to store 64 arbitrary waveform data files, each one of waveform storage depth 8192 points * 14bits; (The longer the waveform storage depth, the more detail the waveform is saved, and the signal details can be restored with high precision.)
- Various modulation types: AM, FM, PM, ASK, FSK and PSK modulations.
- Sweep Function: it can sweep 4 properties of signals including frequency, amplitude, offsets and duty cycle; It has Linear and Logarithm two sweep types; 0.01S~999.99S sweep time; Up, Down and roundtrip sweep directions.
- VCO Function (Voltage Control Output): can be achieved by an external input signal: voltage controlling frequency, voltage controlling amplitude, voltage controlling offsets, voltage controlling duty cycle and PWM modulations.
- Burst Output Function: there has Manual Trigger, internal CH2 Trigger, and External Trigger for your options. It can output 1~1048575 pulse trains.
- 100M Frequency Meter Function: it can measure frequency, period, pulse width and duty cycle. Max. frequency workable is 100MHz and Min. frequency workable is 0.01 Hz.
- Counter Function: it has 2 coupling measure modes including DC coupling and AC coupling. This design can solve inaccuracy problem of AC coupling.
- Standard dual full functional channels which are equivalent to two independent generators.
- Channel SYNC Function: support waveform copy and state copy between channels.
- Support two or more signal generators connected to achieve multi-channel output, the maximum support 16-channel synchronous output, the phase between each channel can be adjusted.
- Precisely adjust the phases of the two channels. Precision can be 0.01°.
- Min amplitude resolution can be up to 1mV. Amplitude range is 0~24Vpp.
- Duty-cycle of each channel can be adjusted independently 0.01%-99.99%, the adjusting resolution is 0.01%.
- -12V~+12V DC Offsets function. Resolution 0.001V.
- Save Function: it can save 20 sets user-set parameters and can be loaded at any time.
- Communicating Function: all functions can be controlled by PC program and the communication protocol is open for secondary development.
- Output Short-circuit Protection: all channels can work more than 60 seconds when the load is short-circuited.
- Provide powerful waveform editing PC software. Users can download arbitrary waveform to this instrument after edit through PC program which is included in user CD.
- Adopt ABS plastic shell with table type design. Use 100-240V (AC) wide range voltage power supply.
Specification:
Plug Type: AU / EU / US / UK (Optional)
Package includes:
1 * DDS Signal Generator
1 * Power Cable
1 * USB Data Cable
1 * BNC-BNC Cable
2 * BNC-Clip Cable
Details pictures:






Quick specs
- Model
- FY6900-100M
- Sine
- 0~100MHz
- Square
- 0~25MHz
- Ramp, Triangle
- 0~10MHz
- Pulse
- 0~10MHz
- TTL/CMOS
- 0~10MHz