1 / 4 · Click to enlarge
AI Summary
A 5V ammonia sensor module that detects NH3 from 5 to 500ppm and provides both analog and digital outputs. Its onboard potentiometer lets you set the digital trigger point for simple leak alarms or Arduino-based monitoring.
Key Highlights
- Detects ammonia across a 5-500ppm concentration range
- Dual output: analog 0-5V and digital TTL signal
- Onboard potentiometer adjusts the digital trigger threshold
- Runs on a 5V supply with heater consumption under 900mW
- Compact 35 x 20mm board weighing about 10g
- Arduino compatible for quick prototyping and alarms
Ideal For
- Makers building Arduino-based gas alarm projects
- Students learning analog and digital sensor interfacing
- Technicians monitoring ammonia in storage or work areas
- Engineers adding ventilation control to a detection system
- Hobbyists logging air quality data over time
Buying Tip
Allow the module a warm-up period on a stable 5V supply before trusting readings, and calibrate the potentiometer against a known ammonia source or reference meter.
Elecvora expert review
Our verdict
A practical, low-cost ammonia sensing module that gives you both analog measurement and a simple digital alarm in one small board. It is best treated as a relative detector that needs warm-up and calibration rather than a laboratory instrument.
AI-assisted analysis based on the manufacturer's specifications. Not a hands-on lab test.
Pros
- Dual analog and digital outputs in one module
- Adjustable digital trigger via onboard potentiometer
- Wide 5-500ppm detection range
- Compact 35 x 20mm board with low weight
- Simple 5V operation for Arduino projects
Cons
- Requires a warm-up period before readings stabilise
- Analog output needs calibration for accurate ppm values
- Heater draws up to 900mW, so a stable supply matters
Best for
Arduino makers and technicians building ammonia leak alarms or air quality monitors
Not ideal for
Users needing certified, lab-grade ammonia measurement out of the box
Specifications
| Item Type | Gas Sensor |
|---|---|
| Operating Voltage (V) | 5 |
| Detection Gas | NH3 |
| Concentration | 5-500ppm (Ammonia) |
| Heater Resistance | 31Ω±3Ω Room Temp. RH |
| Heater power consumption | ≤900mW |
| Sensing resistance | 2KΩ-15KΩ(in 50ppm NH3) Rs |
| Sensitivity | Rs(in air)/Rs(5000ppm CH4)≥5 |
| Output Voltage | 0 ~ 5 |
| Length (mm) | 35 |
| Width (mm) | 20 |
| Weight (g) | 10 |
| Slope(α) | ≤0.6(R100ppm/R50ppm NH3) |
| Shipping Weight | 0.01 kg |
| Shipping Dimensions | 5 × 4 × 1 cm |
What's in the box
- 1 x MQ-137 Ammonia Gas NH3 Sensor Module
Frequently Asked Questions
What gas does this module detect?
What voltage does it need?
Can I connect it directly to an Arduino?
How do I adjust the digital output?
Why are my readings unstable at first?
What is included with the module?
Overview
The MQ-137 is a gas sensor module designed to detect ammonia (NH3) in the air. It combines a heated sensing element with a small breakout board that exposes both an analog voltage output and a digital TTL output, so it can be used for simple threshold alarms or for continuous measurement with a microcontroller. The board measures 35mm by 20mm and weighs around 10g, which makes it easy to fit into enclosures, ducting or handheld builds.
Key Features
- Detection range of 5-500ppm ammonia
- 5V operating voltage with heater power consumption of 900mW or less
- Analog output from 0 to 5V, rising with gas concentration
- Digital TTL output with an adjustable trigger point via onboard potentiometer
- Heater resistance of 31Ω ±3Ω at room temperature and humidity
- Sensing resistance of 2KΩ to 15KΩ in 50ppm NH3
Specifications Explained
Detection range and sensitivity
The module is specified for ammonia concentrations between 5 and 500ppm, with a sensing resistance of 2KΩ to 15KΩ when exposed to 50ppm NH3. The slope figure of 0.6 or less for the R100ppm/R50ppm ratio indicates how the resistance changes between two concentration points, which helps when you build a calibration curve.
Outputs
The analog pin delivers a voltage between 0 and 5V; higher ammonia concentration produces a higher voltage. The digital pin gives a simple high or low TTL signal, and the potentiometer sets the level at which it switches. This makes the board usable either as a quick alarm or as an analog sensing front end.
Heater and power
The sensing element relies on an internal heater with a resistance of 31Ω ±3Ω and a power draw of no more than 900mW at 5V. Because the heater is part of the measurement principle, the module needs a warm-up period before readings become stable.
Compatibility and Requirements
The module operates at 5V and outputs a 0-5V analog signal plus a TTL-level digital signal, so it can connect directly to microcontrollers that accept 5V logic, including Arduino boards. A regulated 5V supply capable of supporting the heater current is required. No additional components are included beyond the module itself.
Typical Uses
- Ammonia leak alarms in workshops and storage areas
- Air quality monitoring projects and data logging
- Ventilation or fan control triggered by gas detection
- Environmental checks in hospitals and laboratories
- Teaching and prototyping gas sensing with Arduino
What's in the Box
One MQ-137 NH3 ammonia gas sensor module.
Quick specs
- Item Type
- Gas Sensor
- Operating Voltage (V)
- 5
- Detection Gas
- NH3
- Concentration
- 5-500ppm (Ammonia)
- Heater Resistance
- 31Ω±3Ω Room Temp. RH
- Heater power consumption
- ≤900mW