Skip to main content

Worldwide Shipping · Secure Payments

AI Summary

The SAIER HW21WA is a turbine water flow sensor that measures 1–30 L/min and runs on 4.5–18V DC. Its pulse output and compact size make it easy to integrate into water heaters, coffee machines, and IoT flow-monitoring projects.

Key Highlights

  • Measures flow rates from 1 to 30 litres per minute
  • Wide 4.5–18V DC operating voltage with ≤15mA current draw
  • Turbine sensing technology with ±10% accuracy
  • Handles working pressure up to 1.75 MPa
  • Digital output: high ≥4.5V, low ≤0.5V
  • Compact design for installation in tight spaces

Ideal For

  • Makers building Arduino or Raspberry Pi flow-monitoring projects
  • Appliance technicians servicing water heaters and coffee machines
  • IoT developers adding flow sensing to smart home systems
  • Industrial automation engineers needing a compact inline sensor
  • Students learning about turbine flow sensors and pulse counting

Buying Tip

Check that your system's flow rate stays within 1–30 L/min and that your microcontroller can handle a 5V pulse output; if using 3.3V logic, plan for a level shifter.

Elecvora expert review

Our verdict

The SAIER HW21WA is a solid, low-cost turbine flow sensor that covers a useful 1–30 L/min range and runs on a wide voltage. It is best suited to hobbyist and light commercial projects where ±10% accuracy is acceptable and a pulse output is easy to integrate.

AI-assisted analysis based on the manufacturer's specifications. Not a hands-on lab test.

Pros

  • Wide 4.5–18V input simplifies power design
  • Low current draw suits battery-powered nodes
  • Compact size fits tight installations
  • Digital pulse output is straightforward to read

Cons

  • ±10% accuracy may not suffice for billing or precision dosing
  • No connector or thread details provided, so plumbing adaptation may be needed
  • Output high level may exceed 3.3V logic, requiring level shifting

Best for

Makers and technicians building flow monitoring into appliances or IoT devices

Not ideal for

Applications demanding high accuracy or sterile medical fluid handling

Specifications

Model No. / NameWater Flow Sensor
Max Water Flow(L/min)1 to 30
Working water pressure(MPa)≤1.75
Operating Voltage (VDC)4.5 to 18
Input current≤15mA
Insulation Resistance (MOhm)>100
Dielectric StrengthAC500V, 50HZ
High Level O/P Volt. (VDD)≥4.5V
Low-level Output Voltage≤0.5V
Accuracy±10%
Shipping Weight0.066 kg
Shipping Dimensions12 × 10 × 3 cm

What's in the box

  • 1 x SAIER HW21WA Water Flow Sensor (1–30 L/min, 4.5–18V)

Frequently Asked Questions

What flow rate can this sensor measure?
It measures from 1 to 30 litres per minute. Flows outside this range may not be detected accurately.
What voltage does the sensor require?
It operates on 4.5 to 18V DC and draws 15mA or less. You can power it from a 5V, 9V, or 12V supply within that range.
What type of output does it provide?
It provides a digital pulse output. The high level is at least 4.5V and the low level is at most 0.5V, suitable for 5V microcontrollers.
Can I use it with a 3.3V microcontroller?
The output high level may be too high for 3.3V inputs, so use a level shifter or voltage divider on the signal line.
What is included in the package?
The package includes one SAIER HW21WA water flow sensor. No tubing, fittings, or cables are mentioned.
How should I maintain the sensor?
Keep the turbine free of debris and avoid corrosive liquids. Flush the line if particles are present to prevent jamming.

Overview

The SAIER HW21WA is a turbine-type water flow sensor built for accurate, repeatable measurement of liquid flow in the 1–30 L/min range. It operates from a 4.5–18V DC supply and produces a digital pulse output that is easy to read with a microcontroller or counter. The sensor is compact, lightweight, and designed for inline installation, making it a practical choice for both prototyping and production equipment.

Key Features

  • Wide flow range: Covers 1 to 30 litres per minute, suitable for low and moderate flow applications.
  • Flexible power: Accepts 4.5–18V DC and draws no more than 15mA, so it can run from small batteries or standard rails.
  • Turbine accuracy: Provides ±10% accuracy across the specified range.
  • Digital output: High level ≥4.5V (VDD) and low level ≤0.5V for clean logic-level pulses.
  • Pressure rated: Works at pressures up to 1.75 MPa.
  • Compact build: Small footprint allows installation where space is limited.

Specifications Explained

Flow range (1–30 L/min): The sensor outputs pulses proportional to flow; at the low end it can detect small trickles, while the upper limit suits typical domestic and light industrial lines.

Operating voltage (4.5–18V DC): The wide input range means you can power it from a 5V microcontroller board, a 12V battery, or a 9V supply without extra regulation, as long as the current limit is respected.

Current draw (≤15mA): Low power consumption makes it suitable for battery-operated data loggers and remote monitoring nodes.

Accuracy (±10%): This tolerance is typical for low-cost turbine sensors; for best results, calibrate against a known volume if your application requires tighter measurement.

Output levels: The high-level output is at least 4.5V (when VDD is 5V or higher) and the low level is at most 0.5V, ensuring compatibility with 5V logic inputs. If you use a 3.3V microcontroller, a level shifter or voltage divider may be needed on the output.

Pressure (≤1.75 MPa): Equivalent to about 17.5 bar, this covers most household and light industrial water systems.

Insulation resistance (>100 MOhm) and dielectric strength (AC500V, 50Hz): These indicate good electrical isolation for a sensor in a wet environment.

Compatibility and Requirements

The HW21WA requires a DC power supply within 4.5–18V and a counter or microcontroller capable of reading digital pulses. The output is a pulse train, not an analog voltage, so a digital input or interrupt pin is needed. No specific connector or thread type is listed; plan your plumbing interface accordingly. The sensor is intended for clean, non-corrosive liquids; avoid particles that could jam the turbine.

Typical Uses

Common applications include water heaters, coffee machines, vending machines, water meters, medical testing equipment, and DIY IoT flow monitoring. It can also be used in industrial equipment, agricultural irrigation, and home automation projects where flow feedback is required.

What's in the Box

1 x SAIER HW21WA Water Flow Sensor (1–30 L/min, 4.5–18V).

Quick specs

Model No. / Name
Water Flow Sensor
Max Water Flow(L/min)
1 to 30
Working water pressure(MPa)
≤1.75
Operating Voltage (VDC)
4.5 to 18
Input current
≤15mA
Insulation Resistance (MOhm)
>100
See all specifications