Skip to main content

Worldwide Shipping · Secure Payments

AI Summary

A calibrated, temperature-compensated differential pressure sensor covering ±500 Pa with analog and I2C outputs. Its 0.5 ms response and 12-bit resolution suit low-flow HVAC, medical and automation designs.

Key Highlights

  • Measures differential pressure across a ±500 Pa range
  • Analog output plus digital two-wire interface with CRC protection
  • 12-bit resolution and a fast 0.5 ms response time
  • Calibrated and temperature compensated for stable readings
  • Runs on 3.0 to 3.6 V at under 6 mA current draw
  • Compact PPSU/MABS housing at 82 mm long and under 20 g

Ideal For

  • HVAC control and airflow monitoring engineers
  • Medical device designers needing low-pressure sensing
  • Automotive and industrial system integrators
  • Makers building low-flow or bypass mass flow setups
  • Process automation and burner control developers

Buying Tip

Confirm your host board can supply 3.0 to 3.6 V and handle either the analog output or the CRC-protected two-wire interface before ordering.

Elecvora expert review

Our verdict

The SDP611 pairs a ±500 Pa range with analog and digital outputs in a compact, calibrated package. It is a practical choice for low-pressure measurement where fast response and stable readings matter.

AI-assisted analysis based on the manufacturer's specifications. Not a hands-on lab test.

Pros

  • Dual analog and digital outputs add integration flexibility
  • Calibrated and temperature compensated out of the box
  • Fast 0.5 ms response with 12-bit resolution
  • Low current draw under 6 mA
  • Compact, lightweight PPSU/MABS housing

Cons

  • Narrow 3.0 to 3.6 V supply window
  • Digital interface requires CRC handling on the host side

Best for

Low-pressure differential measurement in HVAC, medical and automation systems

Not ideal for

Projects needing supply voltages outside 3.0 to 3.6 V

Specifications

Item TypePressure Sensor
Sensor TypeDifferential Pressure Sensor
Model No. / NameSDP611
Operating Voltage (V)3.0– 3.6
Current consumption<6
Operating Temperature (°C)-20 to +85 °C
Standard EncapsulationPPSU/MABS enclosure
Flow Range± 250 slm
Response Time (mS)0.5
Measurement Range500 to + 500 Pa
Resolution12 Bits
InterfaceDigital 2-wire interface
Length (mm)82
Width (mm)34.4
Weight (g)<20
Shipping Weight0.03 kg
Shipping Dimensions14 × 9 × 2 cm

What's in the box

  • 1 x Sensirion SDP611 Differential Pressure Sensor ±500 Pa, Analog Output

Frequently Asked Questions

What pressure range does the SDP611 measure?
It measures differential pressure across a ±500 Pa range, covering both positive and negative differentials within that span.
What output options does the sensor provide?
It offers an analog output and a digital two-wire interface, with CRC protection on the digital communication.
What supply voltage does it need?
The sensor operates from 3.0 to 3.6 V and draws under 6 mA.
What is included with the product?
The package contains one Sensirion SDP611 Differential Pressure Sensor ±500 Pa, Analog Output.
What is the operating temperature range?
It is rated for operation from -20 to +85 °C.
How should the sensor be cared for?
Keep it within the rated voltage and temperature limits, and refer to the datasheet in the attachments section for full handling details.

Overview

The Sensirion SDP611 is a differential pressure sensor for designs that need dependable pressure readings in a small package. It covers a measurement range of ±500 Pa and provides both an analog output and a digital two-wire interface, so it can slot into analog signal chains or communicate digitally with a host controller. The sensing element is built on the SF04 chip, and the unit arrives calibrated and temperature compensated.

With a 12-bit resolution and a 0.5 ms response time, the SDP611 is intended for applications where pressure changes need to be tracked quickly and consistently. Its PPSU/MABS enclosure measures 82 mm by 34.4 mm and weighs under 20 g.

Key Features

  • ±500 Pa range: handles both positive and negative differential pressure within the stated span.
  • Dual output: analog output alongside a digital two-wire interface for flexible integration.
  • CRC-protected communication: the digital link includes CRC protection for data integrity.
  • Fast response: 0.5 ms response time supports dynamic pressure measurement.
  • Low power: operates from 3.0 to 3.6 V and draws under 6 mA.
  • Wide temperature window: rated for operation from -20 to +85 °C.

Specifications Explained

Pressure range and resolution: the ±500 Pa span suits low-pressure measurement, and 12-bit resolution gives fine steps across that range. Repeatability below 10 Pa and accuracy better than 0.2% full scale near zero help when small pressure differences matter.

Outputs: the analog output feeds conventional signal conditioning, while the digital two-wire interface carries measurement data with CRC protection. The sensor also supports hold-master I2C communication.

Power and timing: a 3.0 to 3.6 V supply keeps the design simple for low-voltage systems, and current consumption stays under 6 mA. The 0.5 ms response time means readings update quickly.

Flow range: the sensor is specified for a flow range of ±250 slm, making it relevant to low-flow and bypass mass flow arrangements.

Compatibility and Requirements

The SDP611 requires a supply between 3.0 and 3.6 V. Host systems using the digital interface should support the two-wire protocol with CRC handling, and analog readout requires an ADC or signal chain suited to the analog output. Operating temperature must stay within -20 to +85 °C. Refer to the datasheet in the attachments section for full details regarding the product.

Typical Uses

  • HVAC pressure and airflow monitoring
  • Medical equipment requiring low-pressure sensing
  • Automotive pressure measurement tasks
  • Process automation and burner control
  • Bypass mass flow applications

What's in the Box

1 x Sensirion SDP611 Differential Pressure Sensor ±500 Pa, Analog Output.

Quick specs

Item Type
Pressure Sensor
Sensor Type
Differential Pressure Sensor
Model No. / Name
SDP611
Operating Voltage (V)
3.0– 3.6
Current consumption
<6
Operating Temperature (°C)
-20 to +85 °C
See all specifications