1 / 4 · Click to enlarge
AI Summary
The SN-LB-N01-FL is an RS485 oil fume transmitter for pipeline installation, supporting ModBus-RTU for PLC integration. Its anti-corrosion alloy body and low-maintenance sampling design make it suitable for continuous exhaust monitoring.
Key Highlights
- RS485 interface with ModBus-RTU protocol for PLC and host system integration
- Pipeline-mounted design with flange for secure exhaust installation
- Anti-corrosion coated alloy construction for harsh environments
- Response time of 30 seconds or less for timely fume detection
- Low working current of 50 mA or less for efficient operation
- Maintenance-free sampling structure with annual filter cleaning only
Ideal For
- Commercial kitchen exhaust monitoring
- Industrial ventilation system integrators
- PLC and ModBus-RTU network installers
- Building automation and environmental monitoring
- Maintenance teams needing low-upkeep sensors
Buying Tip
Confirm your PLC or controller supports ModBus-RTU over RS485 and that you have a 12–24 V DC supply available at the installation point before ordering.
Elecvora expert review
Our verdict
The SN-LB-N01-FL is a practical, low-maintenance oil fume transmitter for pipeline installations where RS485 ModBus-RTU integration is required. Its robust build and minimal upkeep make it a solid choice for continuous monitoring in commercial and industrial exhaust systems.
AI-assisted analysis based on the manufacturer's specifications. Not a hands-on lab test.
Pros
- RS485 with ModBus-RTU for easy PLC integration
- Anti-corrosion alloy housing for harsh environments
- Low maintenance with annual filter cleaning only
- Fast response time of 30 seconds or less
- Low working current for efficient operation
Cons
- Requires separate 12–24 V DC power supply
- No display or local interface for configuration
- Specific fume concentration range not specified
Best for
Commercial kitchen and industrial exhaust monitoring with PLC integration
Not ideal for
Portable or battery-powered applications
Specifications
| Item Type | Fume Transmitter |
|---|---|
| Model No. / Name | SN LB N01 FL |
| Voltage Rating | 12–24 |
| Response Time(s) | ≤30 |
| Material | Anti corrosion coated alloy |
| Working Current (mA) | ≤50 |
| Length (mm) | 250 |
| Width (mm) | 200 |
| Weight (g) | 342 |
| Shipping Weight | 0.476 kg |
| Shipping Dimensions | 25 × 20 × 8.5 cm |
What's in the box
- 1 x SN-LB-N01-FL Oil Fume Transmitter (RS485)
- 1 x Fitting Accessory Set
Frequently Asked Questions
What protocol does the SN-LB-N01-FL use?
What power supply is required?
How is the transmitter installed?
What maintenance does it need?
What is included in the package?
What is the response time?
Overview
The SN-LB-N01-FL Oil Fume Transmitter is a dedicated sensing device for measuring oil fume concentration in commercial and industrial exhaust systems. It is designed for direct pipeline installation using a flange, ensuring a stable and secure fit in ventilation ducts and industrial exhausts. The transmitter communicates over an RS485 interface using the ModBus-RTU protocol, which allows it to connect with PLCs, host systems, and configuration software for secondary development. Its anti-corrosion coated alloy housing and sampling component are built to withstand high-temperature and high-humidity conditions, making it suitable for demanding environments where consistent fume detection is required.
Key Features
- RS485 with ModBus-RTU: Enables seamless integration with industrial control systems and supports secondary development.
- Pipeline installation: Flange mounting provides a secure fit directly in exhaust ducts.
- Durable construction: Anti-corrosion coated alloy resists harsh conditions.
- Fast response: Responds in 30 seconds or less.
- Low power draw: Working current of 50 mA or less.
- Minimal maintenance: Sampling design requires only annual cleaning of the peripheral filter.
Specifications Explained
Voltage rating (12–24 V): The transmitter accepts a wide range of DC supply voltages, making it compatible with common industrial power sources. Response time (≤30 s): It provides fume concentration updates within half a minute, suitable for continuous monitoring. Working current (≤50 mA): Low current draw helps reduce power consumption in continuous operation. Material: The anti-corrosion coated alloy body protects against corrosive elements in exhaust streams. Dimensions and weight: At 250 mm long, 200 mm wide, and 342 g, it is compact enough for pipeline mounting without excessive bulk.
Compatibility and Requirements
The SN-LB-N01-FL requires a 12–24 V DC power supply and an RS485 network for data communication. It uses the ModBus-RTU protocol, so it can be integrated with PLCs, host systems, and configuration software that support this standard. No additional proprietary hardware is needed for basic operation. The device is intended for pipeline installation and requires a suitable flange fitting for secure mounting.
Typical Uses
This transmitter is ideal for monitoring oil fume levels in commercial kitchen exhaust systems, industrial ventilation ducts, and other exhaust streams where oil fume concentration needs to be tracked. It is also suitable for integration into building automation or environmental monitoring systems that use ModBus-RTU.
What's in the Box
- 1 x SN-LB-N01-FL Oil Fume Transmitter (RS485)
- 1 x Fitting Accessory Set
Quick specs
- Item Type
- Fume Transmitter
- Model No. / Name
- SN LB N01 FL
- Voltage Rating
- 12–24
- Response Time(s)
- ≤30
- Material
- Anti corrosion coated alloy
- Working Current (mA)
- ≤50