Skip to main content

Worldwide Shipping · Secure Payments

AI Summary

The Winsen ZPH02 is a 5V infrared particles sensor that detects PM2.5 dust down to 1 μm. It offers quick warm-up, calibrated consistency and a compact 59.5 × 44.5 mm footprint for air-quality projects.

Key Highlights

  • Infrared particle-counting detection of PM2.5 dust
  • Sensitive to particles 1 μm diameter and larger
  • 5 ±0.2 V DC operation with ≤90 mA current draw
  • Warm-up time of one minute or less
  • Stable output across 0–50 °C and ≤95% RH
  • Compact 59.5 × 44.5 mm module weighing 45 g

Ideal For

  • Makers building PM2.5 air-quality monitors
  • Appliance developers designing air purifiers
  • HVAC technicians integrating dust sensing
  • Students learning about particle sensors
  • Product engineers prototyping portable instruments

Buying Tip

Confirm your project can supply a stable 5 V rail at up to 90 mA and allow one minute of warm-up before relying on readings.

Elecvora expert review

Our verdict

The Winsen ZPH02 is a sensible choice for builders who need a calibrated, compact PM2.5 sensor with a simple 5 V supply and quick warm-up. It is not a precision reference instrument, but it fits many air-quality product and hobby applications.

AI-assisted analysis based on the manufacturer's specifications. Not a hands-on lab test.

Pros

  • Factory aged, debugged and calibrated for consistency
  • Detects particles down to 1 μm
  • Low current draw of ≤90 mA
  • Fast warm-up of one minute or less
  • Compact 59.5 × 44.5 mm module

Cons

  • Requires a regulated 5 V supply within ±0.2 V
  • Operating range limited to 0–50 °C
  • No mounting or interface details provided in the specifications

Best for

Air purifier, HVAC and portable instrument projects needing a compact PM2.5 sensor.

Not ideal for

Applications requiring operation outside 0–50 °C or a supply outside 5 ±0.2 V.

Specifications

Item TypeDust Sensor
Model No. / NameZPH02
Working Current (mA)≤90mA
Operating Voltage5±0.2 V (DC)
Output Voltage5±0.2 V
Additional Specs.Smallest Particles 1 μm Diameter
Warm-Up Time≤1min(device warming-up time)
Operating Temperature (°C)0℃~50℃
Humidity Range≤95%RH
Length (mm)59.5
Width (mm)44.5
Weight (g)45
Shipping Weight0.02 kg
Shipping Dimensions6 × 4 × 2 cm

What's in the box

  • 1 x ZPH02 Particles Sensor

Frequently Asked Questions

What size particles can the ZPH02 detect?
It detects particles with a diameter of 1 μm or larger, which covers the PM2.5 fraction plus some slightly coarser dust.
What power supply does the sensor need?
The ZPH02 operates from 5 ±0.2 V DC and draws up to 90 mA, so use a regulated 5 V rail that can supply that current.
How long does it take to warm up?
The device warming-up time is one minute or less. Allow that period after power-up before relying on readings.
What is included with the sensor?
The package contains one ZPH02 Particles Sensor. No cable or mounting hardware is listed.
What are the operating temperature and humidity limits?
Use the sensor between 0 °C and 50 °C and at relative humidity up to 95% RH.
How should I care for the sensor?
Keep it within the specified voltage, temperature and humidity limits, avoid contaminating the sensing area, and store it in a dry environment when not in use.

Overview

The Winsen ZPH02 is a particles sensor built around infrared PM2.5 detection. It uses a particle-counting principle to sense fine dust in the surrounding air and responds to particles with a diameter of 1 μm or more. This makes it a practical sensing element for anyone building or servicing air-quality equipment that needs a straightforward dust reading rather than a laboratory-grade instrument.

Each sensor is aged, debugged and calibrated before it leaves the factory, so units behave consistently and offer good sensitivity. The module is compact and light, which helps when space inside an enclosure is limited.

Key Features

  • Infrared PM2.5 detection: particle-counting method for fine dust measurement.
  • 1 μm sensitivity: detects particles at or above one micrometre in diameter.
  • 5 V DC supply: operates at 5 ±0.2 V with a current draw of ≤90 mA.
  • Fast warm-up: ready in one minute or less.
  • Wide operating window: 0 °C to 50 °C and up to 95% RH.
  • Factory calibration: aged and debugged for consistent performance.

Specifications Explained

Operating voltage (5 ±0.2 V DC): the sensor expects a well-regulated 5 V rail. Supply outside this tolerance may affect readings or reliability.

Working current (≤90 mA): modest enough for small enclosures and portable instruments, though the 5 V rail should still be able to deliver this current comfortably.

Smallest particle (1 μm): the ZPH02 responds to particles one micrometre and larger, which covers the PM2.5 fraction plus some slightly larger dust.

Warm-up time (≤1 min): allow the device to stabilise after power-up before trusting the output.

Operating temperature and humidity: 0 °C to 50 °C and ≤95% RH define the environment in which the sensor is intended to work.

Dimensions and weight: 59.5 mm long, 44.5 mm wide and 45 g, so it fits neatly into compact product designs.

Compatibility and Requirements

The ZPH02 requires a 5 ±0.2 V DC supply capable of delivering up to 90 mA. It is intended for use within 0 °C to 50 °C and at humidity up to 95% RH. No other interface or mounting details are specified, so plan your enclosure and wiring around the published dimensions of 59.5 × 44.5 mm and the 45 g weight.

Typical Uses

  • Air purifiers and air refreshers
  • Portable air-quality instruments
  • HVAC systems and air conditioners
  • Smoke alarm systems

What's in the Box

1 × ZPH02 Particles Sensor.

Quick specs

Item Type
Dust Sensor
Model No. / Name
ZPH02
Working Current (mA)
≤90mA
Operating Voltage
5±0.2 V (DC)
Output Voltage
5±0.2 V
Additional Specs.
Smallest Particles 1 μm Diameter
See all specifications