1 / 3 · Click to enlarge
AI Summary
A clamp-on liquid level sensor that detects water through a non-metallic container wall, so the probe never touches the fluid and no drilling is needed. It runs on 5 to 24 VDC, reports over RS485 and carries an IP67 ABS housing.
Key Highlights
- Non-contact detection through non-metallic container walls, no drilling required
- Wide 5 to 24 VDC operating voltage for flexible power sources
- RS485 communication for level data in control and monitoring systems
- IP67 ABS housing suits humid and splash-exposed installations
- Works from 0 to 85°C and 5% to 100% humidity
- Low current draw of about 5 mA keeps it easy to power
Ideal For
- Makers building tank level monitoring with an RS485 controller
- Aquarium and water feature owners checking level without drilling glass
- Irrigation and drone spraying system builders
- Medical and laboratory equipment designers
- Smart appliance and pump control integrators
Buying Tip
Check that your tank or pipe is non-metallic and that your controller reads RS485 before ordering, because the sensor cannot sense through metal walls.
Elecvora expert review
Our verdict
A tidy solution when you cannot or will not put a hole in a tank. The 5 to 24 VDC range and RS485 output make it easy to fold into existing control gear, and the IP67 housing handles damp surroundings.
AI-assisted analysis based on the manufacturer's specifications. Not a hands-on lab test.
Pros
- No contact with the liquid, so no fouling or contamination risk
- No drilling needed on non-metallic containers
- Wide 5 to 24 VDC supply range
- RS485 output suits control and monitoring systems
- IP67 ABS housing for wet environments
Cons
- Will not sense through metal container walls
- Requires a controller or logger that reads RS485
- Mounting surface must be flat and clean for reliable readings
Best for
Level monitoring on non-metallic tanks and pipes feeding an RS485 control system
Not ideal for
Metal tanks or simple setups with no RS485-capable controller
Specifications
| Model No. / Name | Water Level Sensor |
|---|---|
| Operating Voltage (VDC) | 5 to 24 |
| Material | ABS |
| Current consumption | 5 |
| Output Current (mA) | 1 to 100 |
| Operating Temperature (°C) | 0 to 85 |
| Communication Mode | RS485 |
| Humidity Range | 5% to 100% |
| Waterproof Level | IP67 |
| Shipping Weight | 0.03 kg |
| Shipping Dimensions | 3 × 3 × 2 cm |
What's in the box
- 1 x XKC-Y25-V Intelligent Non-Contact Liquid Water Level Sensor
Frequently Asked Questions
Does the sensor touch the liquid?
Can it be used on a metal tank?
What power supply does it need?
How does it connect to a controller?
Is it suitable for outdoor or damp locations?
What is included with the sensor?
Overview
The XKC-Y25-V is a non-contact liquid level sensor built for one job: telling you whether liquid is present at a chosen point on a tank or pipe without ever touching that liquid. It clamps to the outside of a non-metallic container and reads through the wall, so the fluid stays sealed in and the container stays intact. That makes it useful where drilling a port is impractical or where the medium is something you would rather not expose a probe to.
Inside, the sensor uses signal processing to interpret the level reading, and the housing is a compact ABS block sealed to IP67. Power comes from a 5 to 24 VDC supply, current consumption is around 5 mA, and level information is reported over an RS485 line with an output current range of 1 to 100 mA.
Key Features
- Non-contact sensing: detects liquid through the wall of a non-metallic container.
- No boring required: mount on the outside of the tank to keep the vessel sealed.
- Broad voltage range: accepts 5 to 24 VDC, covering common adapters and control supplies.
- RS485 communication: integrates with controllers and monitoring systems that read a serial level signal.
- IP67 ABS housing: resists dust and water ingress in damp or outdoor enclosures.
- Environmental range: rated for 0 to 85°C and 5% to 100% humidity.
Specifications Explained
Voltage and current
The 5 to 24 VDC input means the sensor can share a supply with common 5 V, 12 V or 24 V control hardware. Current consumption is about 5 mA, so it adds very little load, and the 1 to 100 mA output current range covers typical signalling needs.
RS485 output
RS485 is a serial communication standard used over longer cable runs in industrial and building control. If your controller or data logger accepts RS485, the sensor can report level state over that bus rather than a simple on/off line.
IP67 and temperature
IP67 means the ABS housing is protected against dust and against temporary immersion, which is relevant around tanks and wet plant areas. The 0 to 85°C operating range and 5% to 100% humidity rating cover most indoor and sheltered outdoor installations.
Compatibility and Requirements
The sensor is designed for non-metallic containers, since it reads through the wall rather than through metal. It needs a 5 to 24 VDC supply and a receiving device that can read an RS485 signal. Confirm that your controller or logger supports RS485 before wiring it in.
Typical Uses
- Water towers and storage tanks
- Sewage and wastewater treatment equipment
- Agricultural and drone irrigation systems
- Medical equipment and laboratory setups
- Aquariums and smart appliances
What's in the Box
1 x XKC-Y25-V Intelligent Non-Contact Liquid Water Level Sensor.
Quick specs
- Model No. / Name
- Water Level Sensor
- Operating Voltage (VDC)
- 5 to 24
- Material
- ABS
- Current consumption
- 5
- Output Current (mA)
- 1 to 100
- Operating Temperature (°C)
- 0 to 85