Skip to main content

Worldwide Shipping · Secure Payments

AI Summary

The XKC-Y26-V is a non-contact liquid level switch that detects water and other liquids through non-metallic container walls. It runs on 5-12V and provides a switched output, so you can mount it externally without drilling or risking contamination.

Key Highlights

  • Non-contact detection through non-metallic container walls
  • Wide 5-12V operating voltage range
  • Output current 1-100mA for direct load control
  • Fast 500ms response time
  • Compact ABS housing with 45cm cable
  • Works with water, acids, alkalis and other liquids

Ideal For

  • Makers building automated water tanks
  • Aquarium and hydroponics hobbyists
  • Drone irrigation system designers
  • Medical equipment technicians
  • Smart home appliance developers

Buying Tip

Confirm your container is non-metallic and that your load draws no more than 100mA, or use a relay for higher currents.

Elecvora expert review

Our verdict

The XKC-Y26-V is a practical non-contact level switch that simplifies liquid detection in non-metallic tanks. Its wide voltage range and decent output current make it versatile for small-scale automation.

AI-assisted analysis based on the manufacturer's specifications. Not a hands-on lab test.

Pros

  • No direct contact with liquid, reducing contamination and corrosion
  • Easy external mounting without drilling
  • Works with a wide range of liquids including chemicals
  • Low power consumption

Cons

  • Only works with non-metallic containers
  • Output current limited to 100mA, may need a relay for larger loads
  • Response time of 500ms may be slow for fast-changing levels

Best for

Hobbyists and engineers needing a reliable, non-invasive level switch for non-metallic tanks.

Not ideal for

Metal containers or applications requiring direct contact sensing.

Specifications

Operating Voltage (VDC)5 to 12
Model No. / NameXKC-Y26-V
Current consumption5
Output Current (mA)1~100
Response Time (mS)500ms
Operating Temperature (°C)0~85
Operating humidity5~100%
MaterialABS
Cable Length45
Length (mm)18
Width (mm)13
Weight (g)45
Shipping Weight0.05 kg
Shipping Dimensions3 × 2 × 2 cm

What's in the box

  • 1 x XKC-Y26-V Non-contact Liquid Level Sensor Switch

Frequently Asked Questions

Does this sensor work with metal containers?
No, the XKC-Y26-V is designed for non-metallic containers only, as metal walls interfere with the sensing signal.
What is the maximum load I can connect directly?
The output can handle up to 100mA, so you can connect small devices like LEDs or buzzers directly. For pumps or solenoids, use a relay.
Can I use this sensor with a 24V power supply?
No, the operating voltage is 5 to 12VDC. Using 24V may damage the sensor.
Is the sensor waterproof?
The sensor is designed for external mounting and is not intended for immersion. It should be kept dry on the outside.
What is included in the package?
The package includes one XKC-Y26-V non-contact liquid level sensor with a 45cm cable.
How do I clean the sensor?
Wipe the exterior with a dry or slightly damp cloth. Do not use solvents or immerse in water.

Overview

The XKC-Y26-V is an intelligent non-contact liquid level sensor designed to detect the presence or absence of liquid through the wall of a non-metallic container. Unlike float switches or conductive probes, it does not come into direct contact with the liquid, so it is not affected by scale, impurities or aggressive chemicals. The sensor is mounted externally, typically under or against the container, and uses advanced signal processing to detect the liquid level even through thick walls or in airtight vessels.

With a 5-12V operating range and a switched output capable of handling 1-100mA, the XKC-Y26-V can drive small loads directly or interface with microcontrollers, relays and PLCs. Its compact ABS housing and 45cm cable make it easy to integrate into new or existing systems.

Key Features

  • Non-contact detection: senses liquid through non-metallic walls without drilling or direct contact.
  • Wide voltage compatibility: operates from 5 to 12VDC, suiting common power adapters and battery systems.
  • Flexible output: switched output rated 1-100mA for direct control of small pumps, LEDs or relay coils.
  • Fast response: 500ms response time for timely level changes.
  • Durable construction: ABS housing resists moisture and operates from 0 to 85°C and 5-100% humidity.
  • Easy installation: external mounting avoids tank modification and reduces leak risk.

Specifications Explained

Operating voltage (5-12VDC): The sensor works with most 5V and 12V power supplies, making it suitable for USB power, battery packs and industrial control panels. Always ensure the supply is within this range.

Current consumption (5mA): Low power draw means the sensor can be left on continuously without draining small batteries quickly.

Output current (1-100mA): The switched output can directly drive small loads such as indicator lamps, buzzers or relay coils. For larger loads, use an external relay or contactor.

Response time (500ms): The sensor updates its output within half a second of a level change, which is adequate for most tank filling and alarm applications.

Operating temperature (0-85°C) and humidity (5-100%): The sensor is suitable for indoor and outdoor use in many climates, but avoid freezing conditions and direct immersion.

Dimensions and cable: The 18 x 13mm body and 45cm cable allow flexible placement in tight spaces.

Compatibility and Requirements

The XKC-Y26-V is designed for non-metallic containers such as plastic, glass or ceramic. It requires a power supply between 5 and 12VDC and a load that does not exceed 100mA if connected directly. The sensor output is a switched signal; the exact wiring configuration should be confirmed with the markings on the unit. No additional controller is required for basic operation, but for logic-level integration, check that the output voltage is compatible with your microcontroller.

Typical Uses

  • Water tower and tank level monitoring
  • Sewage treatment and sump pump control
  • Drone irrigation system reservoirs
  • Medical equipment and laboratory apparatus
  • Aquarium and hydroponic water level alarms
  • Smart appliances and home automation

What's in the Box

1 x XKC-Y26-V Non-contact Liquid Level Sensor Switch with 45cm cable.

Quick specs

Operating Voltage (VDC)
5 to 12
Model No. / Name
XKC-Y26-V
Current consumption
5
Output Current (mA)
1~100
Response Time (mS)
500ms
Operating Temperature (°C)
0~85
See all specifications