1 / 4 · Click to enlarge
AI Summary
Compact Hall effect flow sensor that outputs digital pulses proportional to water flow from 2 to 100 L/min. Ideal for water heater inlets, DIY controllers, and flow monitoring projects.
Key Highlights
- Measures flow rates from 2 to 100 L/min with digital pulse output
- Hall sensor is epoxy-encapsulated and isolated from water
- Stainless steel bearing and embedded ball for sensitive rotation
- Works in media temperatures from 0 to 80°C and humidity 35–90% RH
- Compact 115 mm body with porous design for small-flow detection
Ideal For
- Makers building Arduino or Raspberry Pi flow-monitoring projects
- Appliance technicians servicing water heaters and inlet systems
- Engineers prototyping dosing or fluid-control equipment
- Students learning about Hall effect sensors and pulse counting
- DIY enthusiasts adding flow feedback to home water systems
Buying Tip
Confirm your controller can count digital pulses and that your typical flow rate falls between 2 and 100 L/min before ordering.
Elecvora expert review
Our verdict
The YF-G1 is a solid, no-frills flow sensor for hobbyists and technicians who need a pulse output proportional to water flow. It offers a useful flow range and a protected Hall element, though it requires a compatible controller and careful installation to perform well.
AI-assisted analysis based on the manufacturer's specifications. Not a hands-on lab test.
Pros
- Wide 2–100 L/min flow range suits many small to medium systems
- Hall sensor is epoxy-encapsulated and isolated from water
- Stainless steel bearing and ball support smooth rotor rotation
- ROHS-compliant materials and compact 115 mm body
Cons
- Requires a controller or meter to interpret pulses; no display or connector provided
- Not suitable for harsh chemicals or temperatures above 80°C
- May need an inlet filter in poor water quality conditions
Best for
DIY electronics and appliance repair projects needing inline flow feedback
Not ideal for
Precision laboratory flow measurement or high-temperature/chemical applications
Specifications
| Max Water Flow(L/min) | 2 to 100 |
|---|---|
| Working water pressure(MPa) | ≤1.75 |
| Operating Temperature (°C) | 0 to 80 |
| Operating humidity | 35 to 90% RH |
| Output Format | Digital Pulses |
| Length (mm) | 115 |
| Width (mm) | 59 |
| Weight (g) | 150 |
| Shipping Weight | 0.17 kg |
| Shipping Dimensions | 7 × 5 × 2 cm |
What's in the box
- 1 x YF-G1 Water Flow Sensor
Frequently Asked Questions
What is the output signal of the YF-G1 sensor?
Can I connect this sensor directly to an Arduino?
What is the maximum water pressure and temperature?
What is included in the package?
How should I maintain the sensor?
Does the sensor work with low flow rates?
Overview
The YF-G1 Water Flow Sensor is an inline flow meter that combines a plastic valve body, a magnetic rotor assembly, and a Hall effect sensor to translate water movement into a clean digital pulse signal. As water passes through the rotor, the magnetic rotor spins at a speed proportional to the flow rate, and the Hall element outputs pulses that a controller can count to determine flow volume or rate. This makes the sensor a straightforward building block for systems that need to react to water flow, such as water heaters, dosing equipment, or custom monitoring setups.
Key Features
- Digital pulse output: Generates a pulse train that is easy to read with most microcontrollers and control boards.
- Hall element protection: The Hall sensor is epoxy resin encapsulated and isolated from the water path, helping resist oxidation and moisture ingress.
- Sensitive rotor: The impeller rotates around a full stainless steel bearing with an embedded stainless steel ball, promoting smooth rotation and reliable low-flow response.
- Stable sealing: The sealing ring uses an upper and lower force structure that is designed to remain unaffected by thermal expansion and contraction.
- Porous flow design: The internal geometry allows even small flows to be sensed as usual, supporting the lower end of the 2–100 L/min range.
- ROHS-compliant materials: All raw materials are stated to comply with ROHS testing standards.
Specifications Explained
Flow range (2–100 L/min): The sensor is intended for systems where flow stays within this band. It is not a precision laboratory meter, but it gives useful feedback for control and monitoring in this range.
Working pressure (≤1.75 MPa): This is the maximum water pressure the body should see in service. Keep your system’s pressure below this value for safe operation.
Operating temperature (0–80°C): The medium temperature should stay within this range. Note that the source description mentions a 120°C limit, but the product data specifies 0–80°C; always follow the 0–80°C figure for this listing.
Output format (digital pulses): The sensor does not output an analog voltage or a bus signal. It produces pulses, so your controller needs a pulse-counting input or an interrupt-capable pin.
Dimensions and weight: At 115 mm long, 59 mm wide, and 150 g, the sensor is compact enough for tight installations while remaining robust.
Compatibility and Requirements
The YF-G1 is a passive pulse-output device. It requires a controller or meter that can count digital pulses and a suitable power supply as specified by your control system. No connector type, cable length, or voltage range is provided in the product data, so check your controller’s input requirements before wiring. The sensor is designed for inline installation and is not a standalone display unit. It is not intended for use with chemicals that could erode the plastic body or internal components.
Typical Uses
- Water inlet flow detection on water heaters and similar appliances
- DIY flow monitoring with Arduino, Raspberry Pi, or other microcontroller platforms
- Dosing and mixing systems that need flow feedback
- Educational projects and prototyping of fluid control systems
What's in the Box
Package includes: 1 x YF-G1 Water Flow Sensor. Note: the sticker may read ZJ-G1; product functionality remains the same.
Quick specs
- Max Water Flow(L/min)
- 2 to 100
- Working water pressure(MPa)
- ≤1.75
- Operating Temperature (°C)
- 0 to 80
- Operating humidity
- 35 to 90% RH
- Output Format
- Digital Pulses
- Length (mm)
- 115