Skip to main content

Worldwide Shipping · Secure Payments

AI Summary

A compact laser particulate matter sensor reporting PM1.0, PM2.5 and PM10 over UART, IIC or PWM from a 5 V supply. The opposite-side air inlet and outlet layout supports steady airflow for consistent readings.

Key Highlights

  • Detects PM1.0, PM2.5 and PM10 particles from 0.3 to 10 µm
  • Three output options: UART, IIC and PWM on an 8-pin header
  • 0 to 1000 µg/m³ measurement range for everyday air monitoring
  • Settles in under 10 seconds after power-on for fast data
  • Runs from 5 V with working current of 85 mA or less
  • Compact 37.8 x 34.8 x 11.8 mm housing with opposite-side ports

Ideal For

  • Makers building indoor air quality monitors
  • Environmental researchers collecting particulate data
  • Product engineers prototyping ventilation controls
  • Students learning sensor integration with UART, IIC or PWM
  • IoT developers adding PM1.0, PM2.5 and PM10 readings

Buying Tip

Confirm your controller supports UART, IIC or PWM and source the matching 8-pin connector before ordering, since neither a connector nor a converter is included.

Elecvora expert review

Our verdict

A practical particulate sensor for builders who want PM1.0, PM2.5 and PM10 data with a choice of three output protocols. Its compact size and fast settling make it easy to fit into monitoring projects, provided you handle the connector and wiring yourself.

AI-assisted analysis based on the manufacturer's specifications. Not a hands-on lab test.

Pros

  • Three particle channels in one compact module
  • UART, IIC and PWM output flexibility
  • Settles in under 10 seconds
  • Low working current of 85 mA or less
  • Wide -10 to +60 °C operating range

Cons

  • Connector and converter are not included
  • No calibration certificate or accuracy data beyond the stated tolerance
  • Requires a regulated 5 V supply and some wiring skill

Best for

Makers and engineers building particulate monitoring devices

Not ideal for

Plug-and-play users who want a pre-wired, enclosed monitor

Specifications

Item TypeSensor
Model No. / NameMPM10 CS
Voltage Rating5
Working Current (mA)≤85mA
Standby current(mA)≤45000mA
Response Time(s)Comprehensive ≤10
Output formUART / IIC / PWM
Operating Temperature (°C)-10~+60
Storage Temperature (°C)-30~+70
Humidity Range0-95% RH (without condensation)
Dimensions (L x W x H) mm37 . 8 x 34 . 8 x 11.8mm
Shipping Weight0.022 kg
Shipping Dimensions11 × 7 × 3 cm

What's in the box

  • 1 x MemsFrontier MPM10-CS Laser PM Sensor (opposite-side air inlet and outlet, 8-pin)

Frequently Asked Questions

What particles does the MPM10-CS measure?
It reports PM1.0, PM2.5 and PM10 concentrations, covering particle sizes from 0.3 to 10 µm.
What output options does the sensor support?
The 8-pin interface provides UART, IIC and PWM output, so you can pick the protocol your controller handles.
What power supply does it need?
It is rated for 5 V and draws 85 mA or less during normal working operation.
Is a connector or converter included?
No. The module ships without a connector or converter, so you need to source the matching part or wire it directly.
What is the measurement range?
Concentrations from 0 to 1000 µg/m³ are covered, with accuracy of ±15 µg/m³ or ±15% of the reading under standard conditions.
How should I care for the sensor?
Keep humidity within 0 to 95% RH without condensation, store between -30 and +70 °C, and avoid blocking the inlet and outlet.

Overview

The MemsFrontier MPM10-CS is a laser particulate matter sensor built for continuous air quality measurement. It reports PM1.0, PM2.5 and PM10 concentrations and covers a measurement range of 0 to 1000 µg/m³, so it suits both indoor monitoring and general environmental projects. The air inlet and outlet are placed on opposite sides of the housing, which encourages a straight airflow path through the sensing area.

An 8-pin interface provides UART, IIC or PWM output, letting you choose the protocol that fits your microcontroller or data logger. The module is compact at 37.8 x 34.8 x 11.8 mm and runs from a 5 V supply.

Key Features

  • Three particle channels: separate readings for PM1.0, PM2.5 and PM10.
  • Flexible output: UART, IIC or PWM selectable through the 8-pin connection.
  • Fast settling: comprehensive response time of 10 seconds or less.
  • Wide operating window: works from -10 to +60 °C and 0 to 95% RH without condensation.
  • Efficient power use: 5 V rated voltage with working current of 85 mA or less.

Specifications Explained

Measurement range and accuracy

The sensor covers concentrations from 0 to 1000 µg/m³ and detects particles from 0.3 to 10 µm. Accuracy is specified as ±15 µg/m³ or ±15% of the reading under standard conditions of 25±2 °C and 50±10% RH, giving you a clear reference point for calibrating expectations in your application.

Output and response

UART, IIC and PWM outputs mean the module can talk to a wide range of host boards without extra circuitry for protocol conversion. The comprehensive response time of 10 seconds or less and the power-on settling time under 10 seconds help you get usable data quickly after startup.

Environmental limits

Operation is rated from -10 to +60 °C, with storage from -30 to +70 °C. Humidity should stay between 0 and 95% RH without condensation, so avoid placing the sensor where moisture can collect.

Compatibility and Requirements

The module needs a regulated 5 V supply and a host device that can read UART, IIC or PWM signals. A connector and a converter are not included, so you will need to source the matching connector or solder your own leads. The 8-pin layout carries the data and power connections for the selected output mode.

Typical Uses

  • Indoor air quality monitors and displays
  • Ventilation and filtration control prototypes
  • Environmental research and data logging
  • Industrial process monitoring where particulate levels matter
  • Educational builds exploring sensor integration

What's in the Box

One MemsFrontier MPM10-CS laser PM sensor with the air inlet and outlet on opposite sides and an 8-pin interface. No connector or converter is supplied.

Quick specs

Item Type
Sensor
Model No. / Name
MPM10 CS
Voltage Rating
5
Working Current (mA)
≤85mA
Standby current(mA)
≤45000mA
Response Time(s)
Comprehensive ≤10
See all specifications