1 / 3 · Click to enlarge
AI Summary
A compact 5 V laser particulate sensor that measures PM1.0, PM2.5 and PM10 through front-facing air inlet and outlet ports. Its 10-pin interface offers UART, IIC and PWM outputs for flexible integration into air quality projects.
Key Highlights
- Measures PM1.0, PM2.5 and PM10 particulate matter concentrations
- Front-mounted air inlet and outlet simplify enclosure and duct design
- 10-pin interface with UART, IIC and PWM output options
- 1 µg/m³ particle mass concentration resolution
- 5 V operation with working current up to 85 mA
- Compact 47 x 36.8 x 11.8 mm module
Ideal For
- Makers building indoor air quality monitors
- HVAC and air purifier product developers
- Environmental researchers collecting particulate data
- Electronics students prototyping sensor projects
- Integrators needing a compact PM sensing module
Buying Tip
Check that your host board supports 5 V logic and one of UART, IIC or PWM before ordering, and plan for a mating connector since none is included.
Elecvora expert review
Our verdict
A well-rounded particulate sensor for builders who want three PM size categories and flexible output options in a compact front-flow package. It is a module, not a finished instrument, so plan for wiring and enclosure work.
AI-assisted analysis based on the manufacturer's specifications. Not a hands-on lab test.
Pros
- Front inlet and outlet simplify enclosure airflow design
- UART, IIC and PWM outputs cover many host boards
- Measures PM1.0, PM2.5 and PM10 in one module
- 1 µg/m³ resolution and 0 to 1000 µg/m³ PM2.5 range
- Compact 47 x 36.8 x 11.8 mm footprint
Cons
- No connector or converter included in the package
- Requires a stable 5 V supply and integration work
- Not a standalone monitor with display or logging
Best for
Embedded air quality monitoring and ventilation control projects
Not ideal for
Users wanting a plug-and-play finished air quality meter
Specifications
| Item Type | Sensor |
|---|---|
| Model No. / Name | MPM11 BD |
| Voltage Rating | 5 |
| Working Current (mA) | ≤85mA |
| Standby current(mA) | ≤45000mA |
| Response Time(s) | Comprehensive ≤10 |
| Output form | UART / IIC / PWM |
| Operating Temperature (°C) | -10~+60 |
| Storage Temperature (°C) | -30~+70 |
| Humidity Range | 0~99%RH(no condensation) |
| Dimensions (L x W x H) mm | 47*36.8*11.8mm |
| Shipping Weight | 0.026 kg |
| Shipping Dimensions | 9 × 7 × 3 cm |
What's in the box
- 1 x MemsFrontier MPM11-BD Laser PM Sensor (front air inlet and outlet, 10 pin)
Frequently Asked Questions
What particles does the MPM11-BD measure?
What output interfaces are available?
What power supply does it need?
Does the package include a cable or connector?
What are the operating conditions?
How accurate are the readings?
Overview
The MemsFrontier MPM11-BD is a laser particulate matter sensor built for embedding into air quality monitoring and ventilation products. It detects PM1.0, PM2.5 and PM10 particles and reports mass concentration values over a digital interface, making it a practical sensing block for developers, integrators and advanced makers.
Both the air inlet and the air outlet are located on the front of the module. That layout gives designers more freedom when routing airflow inside a housing, because the sampling path does not need to wrap around the board.
Key Features
- Particulate detection across PM1.0, PM2.5 and PM10 categories
- Particle detection diameter range of 0.3 to 10 micrometres
- 10-pin connection for data output and power
- Selectable UART, IIC or PWM output form
- Particle mass concentration resolution of 1 µg/m³
- PM2.5 standard value range of 0 to 1000 µg/m³
- Compact footprint of 47 x 36.8 x 11.8 mm
Specifications Explained
Voltage and current: the module runs from a 5 V supply and draws up to 85 mA while working, so a stable 5 V rail with modest headroom is enough for most controller boards.
Output form: UART, IIC and PWM options mean the sensor can talk to a wide range of host devices. Choose the interface that matches your firmware and wiring plan.
Response time: the comprehensive response time is 10 seconds or less, so readings settle quickly after power-up and during normal sampling.
Accuracy and consistency: under standard conditions the tolerance is ±15 µg/m³ or ±15% of reading. Consistency within the PM2.5 standard value is ±10% for 100 to 500 µg/m³ and ±10 µg/m³ for 0 to 100 µg/m³.
Environmental limits: operation is rated from -10 to +60 °C and 0 to 99% RH without condensation, with storage from -30 to +70 °C.
Compatibility and Requirements
The MPM11-BD needs a 5 V supply and a host that can read UART, IIC or PWM. Note that the module is supplied without a connector or converter, so you will need to source mating hardware and wiring for your own build. Always confirm pinout and signal levels against the module documentation before connecting power.
Typical Uses
- DIY and commercial air quality monitors
- Air purifier and ventilation control feedback
- Environmental monitoring and research projects
- Industrial process and indoor air assessment
- Educational and prototyping platforms
What's in the Box
1 x MemsFrontier MPM11-BD laser PM sensor with front air inlet and outlet and a 10-pin interface. A connector and converter are not included.
Quick specs
- Item Type
- Sensor
- Model No. / Name
- MPM11 BD
- Voltage Rating
- 5
- Working Current (mA)
- ≤85mA
- Standby current(mA)
- ≤45000mA
- Response Time(s)
- Comprehensive ≤10