
1 / 3 · Click to enlarge
AI Summary
A compact I2C breakout built around Sensirion's SGP40 MOX gas sensor that reports a processed VOC index from 0 to 500. STEMMA QT/Qwiic connectors and 3-5 V operation make it easy to add indoor air quality sensing to almost any microcontroller.
Key Highlights
- Sensirion SGP40 MOX gas sensor with integrated heater control
- Processed VOC index output from 0 to 500 over I2C
- Fixed I2C address 0x59 for simple bus integration
- Wide 3 to 5 V operating voltage range
- STEMMA QT/Qwiic connectors for solder-free cabling
- Supports humidity compensation when fed an external RH reading
Ideal For
- Makers building indoor air quality monitors
- Students learning about gas sensors and I2C
- Prototypers adding environmental sensing to a product
- Home automation enthusiasts logging VOC trends
- Educators demonstrating sensor calibration concepts
Buying Tip
Plan for an external humidity sensor and a calibration reference if you need accurate absolute readings, since MOX gas sensors vary between units.
Elecvora expert review
Our verdict
The SGP40 breakout removes most of the friction from MOX gas sensing by handling heater control and signal processing internally. It is a sensible choice for trend-based indoor air quality projects where ease of integration matters more than laboratory-grade accuracy.
AI-assisted analysis based on the manufacturer's specifications. Not a hands-on lab test.
Pros
- Clean I2C interface with a processed VOC index
- Works across 3 to 5 V systems
- STEMMA QT/Qwiic connectors simplify wiring
- Humidity compensation support improves stability
Cons
- Requires an external humidity sensor for compensation
- MOX sensors need calibration for precise absolute readings
- Fixed I2C address limits multiple units on one bus
Best for
Indoor air quality trend monitoring and environmental data projects
Not ideal for
Applications needing certified or calibrated absolute gas measurements
Specifications
| Item Type | Air Quality Sensor |
|---|---|
| Model No. / Name | SGP40 |
| Operating Voltage (V) | 3 to 5 |
| Interface | I2C Communication Interface Address: 0x59 |
| Measuring Current Range | VOC: 0 ppm to 1000 ppm |
| Measurement Range | VOC Index Value: 0 to 500 |
| Communication Mode | I2C |
| Connector Type | STEMMA QT/Qwiic |
| Shipping Weight | 0.01 kg |
| Shipping Dimensions | 3 × 2 × 1 cm |
What's in the box
- 1 x Adafruit SGP40 Air Quality Sensor Breakout - VOC Index - STEMMA QT/Qwiic
Frequently Asked Questions
What does the VOC index actually represent?
What voltage does the breakout need?
How do I connect it to my board?
Can I connect more than one sensor to the same bus?
Do I need a separate humidity sensor?
Is the sensor calibrated out of the box?
Overview
The Adafruit SGP40 Air Quality Sensor Breakout packages Sensirion's integrated MOX gas sensor into a small, ready-to-wire module. Instead of asking you to drive a heater and interpret a raw analog voltage, the SGP40 combines sensing and heating elements with an onboard controller that communicates over I2C. The result is a straightforward digital air quality signal you can log, display, or act on.
Key Features
- Fully integrated MOX gas sensor with internal heater management
- I2C interface at address 0x59
- VOC index output scaled from 0 to 500
- Detection across a wide range of volatile organic compounds and H2
- Operating voltage of 3 to 5 V
- STEMMA QT/Qwiic connectors for quick daisy-chain wiring
- Humidity compensation supported via an external sensor reading written over I2C
Specifications Explained
VOC index 0 to 500: Rather than a raw resistance figure, the sensor's algorithm produces a single index value that makes trends and comparisons easier to follow. Lower values indicate cleaner air; rising values suggest increasing VOC concentration.
Measuring range 0 to 1000 ppm: The underlying sensing element covers VOC concentrations in this range, while the reported index condenses that response into a 0 to 500 scale.
I2C at 0x59: A fixed address means one device per bus unless you use a multiplexer, and it keeps wiring and code simple.
3 to 5 V supply: The board works with both 3.3 V and 5 V logic systems, covering most common development boards.
Compatibility and Requirements
You need a host microcontroller with an I2C bus and a 3 to 5 V supply. Connection is made through the STEMMA QT/Qwiic connectors or the breakout's header pads. For humidity compensation, an external humidity sensor is required; its reading is sent to the SGP40 over I2C.
Typical Uses
- Indoor air quality monitoring and trend logging
- Ventilation or fan control feedback
- Environmental data displays and dashboards
- Educational gas-sensing experiments
What's in the Box
1 x Adafruit SGP40 Air Quality Sensor Breakout - VOC Index - STEMMA QT/Qwiic.
Quick specs
- Item Type
- Air Quality Sensor
- Model No. / Name
- SGP40
- Operating Voltage (V)
- 3 to 5
- Interface
- I2C Communication Interface Address: 0x59
- Measuring Current Range
- VOC: 0 ppm to 1000 ppm
- Measurement Range
- VOC Index Value: 0 to 500



















