1 / 4 · Click to enlarge
AI Summary
A mikroBUS add-on board carrying the WSP2110 VOC gas sensor for detecting organic gases in the 1 to 50 ppm range. It outputs an analog signal and includes an onboard potentiometer for sensitivity trimming.
Key Highlights
- WSP2110 metal oxide semiconductor VOC gas sensor onboard
- Detection range of 1 to 50 ppm for organic gases
- Analog and GPIO interface over the mikroBUS line
- Onboard P1 potentiometer for sensitivity adjustment
- Runs from a single 5V supply
- Compact 42.9 x 25.4 mm click board format
Ideal For
- Embedded engineers prototyping air quality monitors on mikroBUS platforms
- Developers building automatic exhaust or ventilation control systems
- Makers designing air cleaner and harmful gas detection devices
- Students learning about MOS gas sensors and analog signal conditioning
- Product teams evaluating VOC sensing before a custom design
Buying Tip
Allow the 120-hour preheat period after first power-up before trusting readings, and use the P1 potentiometer to trim sensitivity for your enclosure and gas target.
Elecvora expert review
Our verdict
A tidy, well-documented way to add VOC sensing to a mikroBUS design without building the sensor front end yourself. The 1 to 50 ppm range and analog output suit ambient monitoring prototypes, provided you plan for the long preheat period.
AI-assisted analysis based on the manufacturer's specifications. Not a hands-on lab test.
Pros
- Ready-made mikroBUS board with the WSP2110 sensor fitted
- Sensitivity trim via the onboard P1 potentiometer
- Heater MOSFET gate helps cut idle power consumption
- Compact 42.9 x 25.4 mm footprint
Cons
- Requires a 120-hour preheat for precise calibration
- 5V supply only, so 3.3V-only hosts need level and power planning
- Analog output needs an ADC and firmware calibration work
Best for
Engineers prototyping VOC and air quality monitoring on mikroBUS platforms
Not ideal for
Anyone wanting a calibrated, out-of-the-box gas meter with a digital readout
Specifications
| Item Type | Air Quality Sensor |
|---|---|
| Operating Voltage (V) | 5 |
| Interface | Analog, GPIO |
| Compatibility | mikroBUS |
| Board Size (mm) | 42.9 x 25.4 mm |
| Detecting Range | 1~50ppm |
| On-Board Sensors (Y/N) | WSP2110 VOC gas sensor |
| Shipping Weight | 0.05 kg |
| Shipping Dimensions | 7 × 5 × 2 cm |
What's in the box
- 1 x MIKROE POLLUTION CLICK (MIKROE-2516) WSP2110 VOC Gas Sensor Board
Frequently Asked Questions
What gases does the POLLUTION CLICK detect?
How does the board connect to my microcontroller?
What supply voltage does it need?
Why does the sensor need preheating?
Can I reduce power consumption when it is not in use?
What is included with the product?
Overview
The MIKROE POLLUTION CLICK is a mikroBUS add-on board designed around the WSP2110 VOC gas sensor. The sensor is a metal oxide semiconductor type, meaning its conductivity changes as it is exposed to volatile organic compounds such as methanal, benzene, alcohol and toluene. Higher gas concentration produces higher conductivity, which the host microcontroller reads as an analog signal.
Key Features
- WSP2110 sensor: a MOS VOC sensor that responds to organic gases harmful in high concentrations.
- 1 to 50 ppm range: suited to low-level detection of target gases.
- Analog and GPIO interface: the board communicates over the AN and RST pins on the mikroBUS line.
- P1 potentiometer: trims sensor sensitivity to suit your setup.
- Heater MOSFET gate: enabling the pin drive gate lets you switch the heater off to reduce power consumption when the click is not in use.
- 5V operation: powered from a single 5V rail.
Specifications Explained
The 1 to 50 ppm detection range is expressed in parts per million, the ratio of the target gas to the rest of the gas mixture. This is a low-concentration range, appropriate for monitoring ambient air rather than measuring high-percentage gas streams. The analog output gives a continuous reading, so your firmware can track trends rather than just a threshold. The onboard P1 potentiometer is the practical adjustment point for sensitivity; the datasheet notes a sensitivity figure of Rs in air versus Rs in 10 ppm toluene of at least 3, which indicates how strongly the sensor responds to a target gas. The board measures 42.9 x 25.4 mm.
Compatibility and Requirements
The click is compatible with mikroBUS sockets and requires a 5V supply. It uses the AN and RST pins for communication, so the host board must expose an analog input on the AN line. For precise calibration the sensor needs a preheat period; once powered up it takes 120 hours to reach the right temperature, so plan for a burn-in window before relying on readings.
Typical Uses
- Automatic exhaust devices
- Air cleaners
- Harmful gas detection devices
- Air quality monitoring prototypes on mikroBUS platforms
What's in the Box
One MIKROE POLLUTION CLICK (MIKROE-2516) WSP2110 VOC gas sensor board.
Quick specs
- Item Type
- Air Quality Sensor
- Operating Voltage (V)
- 5
- Interface
- Analog, GPIO
- Compatibility
- mikroBUS
- Board Size (mm)
- 42.9 x 25.4 mm
- Detecting Range
- 1~50ppm