Skip to main content

Worldwide Shipping · Secure Payments

AI Summary

A compact 13 x 13 mm MEMS breakout that senses formaldehyde from 0 to 3 ppm and outputs an analog voltage. It runs on 3.3 to 5 V with under 20 mA draw, making low-power air quality prototyping straightforward.

Key Highlights

  • MEMS formaldehyde sensor with 0–3 ppm HCHO detection range
  • Analog voltage output for direct reading by most microcontrollers
  • Wide 3.3 to 5 V supply with under 20 mA operating current
  • Compact 13 x 13 mm board for tight enclosures and wearables
  • Rapid response and recovery with short preheating time
  • Operating range of -10 to 50 °C and 15–90% RH non-condensing

Ideal For

  • Makers building indoor air quality monitors
  • Hardware developers prototyping air purifier controls
  • Students learning about MEMS gas sensors
  • Engineers designing compact portable detectors
  • Wearable device developers needing low-power sensing

Buying Tip

Remove the protective film before first use and allow a preheat period so the analog reading stabilises before you log data.

Elecvora expert review

Our verdict

A neatly packaged MEMS formaldehyde sensor that is easy to power and read, and small enough for genuinely portable designs. It suits qualitative detection and prototyping rather than calibrated measurement.

AI-assisted analysis based on the manufacturer's specifications. Not a hands-on lab test.

Pros

  • Very small 13 x 13 mm footprint
  • Simple analog output with no protocol setup
  • Low current draw under 20 mA
  • Works across 3.3 to 5 V supplies
  • Long rated life of 3 years or more in air

Cons

  • Qualitative output only, not calibrated ppm
  • Requires an ADC input and some signal interpretation
  • Sensitive to silicone vapours and corrosive gases

Best for

Compact air quality prototypes and formaldehyde trend detection

Not ideal for

Applications needing calibrated, quantitative HCHO measurement or personal safety systems

Specifications

Item TypeGas Sensor
Operating Voltage (V)3.3 to 5
Detecting Range0-3ppm
Detection GasHCHO
Max. Operating Current (A)20
Signal OutputAnalog Voltage
Operating Temperature (°C)-10~50℃
Operating humidity15-90%RH (non-condensing)
Life Cycle≥3 years (in air)
Length (mm)13
Width (mm)13
Weight (g)1 (approx)
Shipping Weight0.012 kg
Shipping Dimensions6 × 6 × 3 cm

What's in the box

  • 1 x DFRobot Fermion MEMS Formaldehyde HCHO Gas Detection Sensor (Breakout, 0–3 ppm)
  • 1 x 2.54 mm pitch header pin

Frequently Asked Questions

What concentration range does this sensor detect?
It is designed for formaldehyde detection from 0 to 3 ppm and outputs an analog voltage that changes with concentration.
Can I connect it directly to a 5 V microcontroller?
Yes. The module accepts a supply from 3.3 V to 5 V, so it works with both 3.3 V and 5 V boards that have an analog input.
Does it give an exact ppm value?
No. The sensor provides qualitative measurements, so use the analog signal to detect presence and trends rather than a calibrated ppm figure.
What is included with the sensor?
You receive the Fermion MEMS Formaldehyde HCHO Gas Detection Sensor breakout and one 2.54 mm pitch header pin.
How should I care for the sensor?
Remove the protective film before use, avoid silicone vapours, corrosive gases, water and condensation, and preheat for at least 24 hours if the module has been unused for a long time.
What are the operating conditions?
The sensor is specified for -10 to 50 °C and 15 to 90% relative humidity, non-condensing, with a life cycle of 3 years or more in air.

Overview

The DFRobot Fermion MEMS Formaldehyde Gas Sensor is a breakout board built around a micro-electromechanical system sensing element. It responds to formaldehyde (HCHO) in the 0 to 3 ppm range and presents the result as an analog voltage that a microcontroller can read directly. At roughly 13 x 13 mm and about 1 g, the module is small enough for handheld and wearable enclosures where conventional gas sensors will not fit.

The sensor is intended for qualitative measurement: it shows whether formaldehyde is present and how the signal trends, rather than delivering a calibrated ppm figure. That makes it well suited to prototyping, threshold alerts and comparative air quality experiments.

Key Features

  • MEMS sensing element: compact construction with low power use and minimal heat generation.
  • Analog voltage output: simple interface to any ADC-equipped board.
  • Flexible supply: operates from 3.3 V to 5 V.
  • Low current: maximum operating current of 20 mA.
  • Fast behaviour: short preheating time with quick response and recovery.
  • Long service life: rated at 3 years or more in air.

Specifications Explained

Detection range and gas

The 0 to 3 ppm window covers the low concentrations relevant to indoor air quality checks and leak-style alerting. The sensor targets HCHO specifically, so readings should be treated as formaldehyde-related signal strength rather than a general air quality index.

Power and signal

A 3.3 to 5 V supply matches common development boards, and the maximum 20 mA current keeps battery budgets modest. The analog voltage output means you connect it to an ADC pin and interpret the change in voltage as the gas concentration shifts.

Environmental limits

Operation is specified from -10 to 50 °C and 15 to 90% relative humidity, non-condensing. Keep the board away from condensation, water and freezing conditions, and avoid prolonged exposure to extreme heat, humidity or heavily polluted air.

Compatibility and Requirements

The board needs a DC supply between 3.3 V and 5 V and a host device with an analog input. A 2.54 mm pitch header pin is supplied for wiring. Because the output is analog and qualitative, no digital protocol or calibration file is required, but a stable reference voltage on your ADC improves consistency.

Typical Uses

  • Air purifier and HVAC control prototypes
  • Smart wearable and portable detector concepts
  • Indoor air quality monitoring experiments
  • Educational projects on gas sensing and MEMS technology

What's in the Box

  • 1 x DFRobot Fermion MEMS Formaldehyde HCHO Gas Detection Sensor (Breakout, 0–3 ppm)
  • 1 x 2.54 mm pitch header pin

Quick specs

Item Type
Gas Sensor
Operating Voltage (V)
3.3 to 5
Detecting Range
0-3ppm
Detection Gas
HCHO
Max. Operating Current (A)
20
Signal Output
Analog Voltage
See all specifications