
1 / 5 · Click to enlarge
AI Summary
A compact 13 x 13 mm MEMS breakout that senses formaldehyde from 0 to 3 ppm and outputs an analog voltage. It runs on 3.3 to 5 V with under 20 mA draw, making low-power air quality prototyping straightforward.
Key Highlights
- MEMS formaldehyde sensor with 0–3 ppm HCHO detection range
- Analog voltage output for direct reading by most microcontrollers
- Wide 3.3 to 5 V supply with under 20 mA operating current
- Compact 13 x 13 mm board for tight enclosures and wearables
- Rapid response and recovery with short preheating time
- Operating range of -10 to 50 °C and 15–90% RH non-condensing
Ideal For
- Makers building indoor air quality monitors
- Hardware developers prototyping air purifier controls
- Students learning about MEMS gas sensors
- Engineers designing compact portable detectors
- Wearable device developers needing low-power sensing
Buying Tip
Remove the protective film before first use and allow a preheat period so the analog reading stabilises before you log data.
Elecvora expert review
Our verdict
A neatly packaged MEMS formaldehyde sensor that is easy to power and read, and small enough for genuinely portable designs. It suits qualitative detection and prototyping rather than calibrated measurement.
AI-assisted analysis based on the manufacturer's specifications. Not a hands-on lab test.
Pros
- Very small 13 x 13 mm footprint
- Simple analog output with no protocol setup
- Low current draw under 20 mA
- Works across 3.3 to 5 V supplies
- Long rated life of 3 years or more in air
Cons
- Qualitative output only, not calibrated ppm
- Requires an ADC input and some signal interpretation
- Sensitive to silicone vapours and corrosive gases
Best for
Compact air quality prototypes and formaldehyde trend detection
Not ideal for
Applications needing calibrated, quantitative HCHO measurement or personal safety systems
Specifications
| Item Type | Gas Sensor |
|---|---|
| Operating Voltage (V) | 3.3 to 5 |
| Detecting Range | 0-3ppm |
| Detection Gas | HCHO |
| Max. Operating Current (A) | 20 |
| Signal Output | Analog Voltage |
| Operating Temperature (°C) | -10~50℃ |
| Operating humidity | 15-90%RH (non-condensing) |
| Life Cycle | ≥3 years (in air) |
| Length (mm) | 13 |
| Width (mm) | 13 |
| Weight (g) | 1 (approx) |
| Shipping Weight | 0.012 kg |
| Shipping Dimensions | 6 × 6 × 3 cm |
What's in the box
- 1 x DFRobot Fermion MEMS Formaldehyde HCHO Gas Detection Sensor (Breakout, 0–3 ppm)
- 1 x 2.54 mm pitch header pin
Frequently Asked Questions
What concentration range does this sensor detect?
Can I connect it directly to a 5 V microcontroller?
Does it give an exact ppm value?
What is included with the sensor?
How should I care for the sensor?
What are the operating conditions?
Overview
The DFRobot Fermion MEMS Formaldehyde Gas Sensor is a breakout board built around a micro-electromechanical system sensing element. It responds to formaldehyde (HCHO) in the 0 to 3 ppm range and presents the result as an analog voltage that a microcontroller can read directly. At roughly 13 x 13 mm and about 1 g, the module is small enough for handheld and wearable enclosures where conventional gas sensors will not fit.
The sensor is intended for qualitative measurement: it shows whether formaldehyde is present and how the signal trends, rather than delivering a calibrated ppm figure. That makes it well suited to prototyping, threshold alerts and comparative air quality experiments.
Key Features
- MEMS sensing element: compact construction with low power use and minimal heat generation.
- Analog voltage output: simple interface to any ADC-equipped board.
- Flexible supply: operates from 3.3 V to 5 V.
- Low current: maximum operating current of 20 mA.
- Fast behaviour: short preheating time with quick response and recovery.
- Long service life: rated at 3 years or more in air.
Specifications Explained
Detection range and gas
The 0 to 3 ppm window covers the low concentrations relevant to indoor air quality checks and leak-style alerting. The sensor targets HCHO specifically, so readings should be treated as formaldehyde-related signal strength rather than a general air quality index.
Power and signal
A 3.3 to 5 V supply matches common development boards, and the maximum 20 mA current keeps battery budgets modest. The analog voltage output means you connect it to an ADC pin and interpret the change in voltage as the gas concentration shifts.
Environmental limits
Operation is specified from -10 to 50 °C and 15 to 90% relative humidity, non-condensing. Keep the board away from condensation, water and freezing conditions, and avoid prolonged exposure to extreme heat, humidity or heavily polluted air.
Compatibility and Requirements
The board needs a DC supply between 3.3 V and 5 V and a host device with an analog input. A 2.54 mm pitch header pin is supplied for wiring. Because the output is analog and qualitative, no digital protocol or calibration file is required, but a stable reference voltage on your ADC improves consistency.
Typical Uses
- Air purifier and HVAC control prototypes
- Smart wearable and portable detector concepts
- Indoor air quality monitoring experiments
- Educational projects on gas sensing and MEMS technology
What's in the Box
- 1 x DFRobot Fermion MEMS Formaldehyde HCHO Gas Detection Sensor (Breakout, 0–3 ppm)
- 1 x 2.54 mm pitch header pin
Quick specs
- Item Type
- Gas Sensor
- Operating Voltage (V)
- 3.3 to 5
- Detecting Range
- 0-3ppm
- Detection Gas
- HCHO
- Max. Operating Current (A)
- 20
- Signal Output
- Analog Voltage


















