1 / 5 · Click to enlarge
AI Summary
A compact MEMS ammonia sensor breakout that outputs an analog voltage for 1–300 ppm NH3 detection. It runs from 3.3–5 V with low current draw, making it easy to add to microcontroller gas-sensing projects.
Key Highlights
- MEMS ammonia sensing element in a 13 × 13 mm breakout
- Detects NH3 across a 1–300 ppm range
- Analog voltage output works with any ADC input
- 3.3 V to 5 V supply with under 20 mA draw
- Short preheat time and fast response recovery
- Rated for at least 5 years of life in air
Ideal For
- Makers building ammonia detection prototypes with an ADC-equipped board
- Students learning about MEMS gas sensors and analog signal reading
- Engineers prototyping cold storage or aquaculture monitoring
- Developers assembling multi-sensor MEMS gas detection arrays
Buying Tip
Remember to peel off the protective film and allow a preheat period before trusting readings, and keep the board away from silicone vapours and condensing moisture.
Elecvora expert review
Our verdict
A neat, low-power ammonia sensing breakout that is easy to wire to any ADC-equipped board and ideal for qualitative detection experiments. It is not a calibrated instrument, so treat readings as trends rather than precise concentrations.
AI-assisted analysis based on the manufacturer's specifications. Not a hands-on lab test.
Pros
- Very compact 13 × 13 mm breakout
- Low current draw under 20 mA
- Works with both 3.3 V and 5 V systems
- Simple analog output, no complex protocol
- Short preheat and fast response
Cons
- Qualitative measurement only, not calibrated
- Sensitive to silicone vapours and corrosive gases
- Not suitable for personal safety systems
Best for
Makers and students prototyping ammonia detection and odour monitoring
Not ideal for
Safety-critical gas detection or calibrated concentration measurement
Specifications
| Item Type | Gas Sensor |
|---|---|
| Operating Voltage (V) | 3.3 to 5 |
| Detecting Range | 1-300ppm |
| Detection Gas | Ammonia (NH3) |
| Max. Operating Current (A) | 20 |
| Signal Output | Analog Voltage |
| Operating Temperature (°C) | -10~50℃ |
| Operating humidity | 15-90%RH (non-condensing) |
| Life Cycle | ≥5 years (in air) |
| Length (mm) | 13 |
| Width (mm) | 13 |
| Weight (g) | 1 (approx) |
| Shipping Weight | 0.012 kg |
| Shipping Dimensions | 6 × 6 × 3 cm |
What's in the box
- 1 × DFRobot Fermion MEMS Ammonia NH3 Gas Detection Sensor (Breakout, 1–300 ppm)
- 1 × 2-pin connector
Frequently Asked Questions
What concentration range does this sensor detect?
What output does the board provide?
What supply voltage does it need?
Can I use it for precise ammonia measurement?
What should I do before first use?
What should I avoid exposing the sensor to?
Overview
The DFRobot Fermion MEMS NH3 Ammonia Gas Sensor is a small breakout board for detecting ammonia in air. Its sensing element uses micro-electromechanical system (MEMS) technology, which keeps the package compact at roughly 13 × 13 mm and the power demand low. The board outputs an analog voltage that responds to ammonia concentration between 1 and 300 ppm, so a microcontroller with an analog-to-digital converter can read it directly.
This module is designed for qualitative detection: it helps you see whether ammonia is present and how the level trends, rather than delivering a calibrated, traceable concentration figure. That makes it well suited to experiments, prototypes, and monitoring setups where a simple analog signal is enough.
Key Features
- MEMS sensing element: compact construction with low heat generation and a short preheat time.
- Wide detecting range: responds to ammonia from 1 ppm up to 300 ppm.
- Analog output: a simple voltage signal that any ADC-equipped board can read.
- Flexible supply: operates from 3.3 V to 5 V, with a maximum operating current of 20 mA.
- Fast response and recovery: quick to react when gas appears and to settle when it clears.
- Long service life: rated for at least 5 years in air.
Specifications Explained
Detecting range (1–300 ppm): the sensor is most useful in the low-to-moderate ammonia concentrations typical of leak checks and odour monitoring. Readings outside this band are not specified.
Operating voltage (3.3–5 V): the board works with both common logic levels, so it can share a supply with 3.3 V and 5 V microcontrollers alike.
Current (max 20 mA): low enough for battery-powered builds and for sharing a regulator with other low-power modules.
Analog voltage signal: you read the sensor through an ADC pin. Expect to characterise the response in your own setup rather than relying on a factory calibration curve.
Environment (-10 to 50 °C, 15–90 %RH non-condensing): keep the board away from condensation, water, and freezing conditions, and avoid prolonged exposure to extreme heat, humidity, or heavy pollution.
Compatibility and Requirements
The sensor needs a host board with an analog input and a 3.3 V or 5 V supply. Because the output is a plain analog voltage, it is not tied to a particular microcontroller family. You will need to remove the protective film before first use and allow a preheat period for stable readings. For systems that involve personal safety, this module should not be used.
Typical Uses
- Ammonia leak checks in cold storage areas
- Aquaculture risk-control experiments
- Toilet and washroom odour monitoring prototypes
- Classroom and maker gas-sensing projects
- Combining with other Fermion MEMS gas sensors in a multi-sensor array
What's in the Box
- 1 × DFRobot Fermion MEMS Ammonia NH3 Gas Detection Sensor (Breakout, 1–300 ppm)
- 1 × 2-pin connector

Quick specs
- Item Type
- Gas Sensor
- Operating Voltage (V)
- 3.3 to 5
- Detecting Range
- 1-300ppm
- Detection Gas
- Ammonia (NH3)
- Max. Operating Current (A)
- 20
- Signal Output
- Analog Voltage