1 / 3 · Click to enlarge
AI Summary
A wall-mounted industrial ammonia sensor for livestock farms, measuring 0-100ppm with 0.1ppm resolution and sending readings over RS485. Its DC 10-30V input and waterproof housing support continuous barn monitoring.
Key Highlights
- 0-100ppm ammonia range with 0.1ppm resolution in the lower band
- RS485 output for integration with control and monitoring systems
- Waterproof wall-mounted design measuring 140 x 90mm at 133g
- Wide DC 10-30V power supply for flexible installation
- Operates from -20 to 50 degrees Celsius and 15-90%RH
- Accuracy of plus or minus 8% across the 0-100ppm span
Ideal For
- Livestock and poultry farm operators monitoring barn air quality
- Agricultural integrators building RS485-based ventilation control
- Facility managers tracking ammonia levels continuously
- Technicians installing wall-mounted gas monitoring points
Buying Tip
Confirm your controller or logger accepts RS485 and can supply DC 10-30V before ordering, since this model communicates only over RS485.
Elecvora expert review
Our verdict
A focused, purpose-built ammonia sensor for livestock housing that pairs a 0-100ppm range with RS485 output and a waterproof wall-mount housing. It is a sensible pick when you need continuous barn readings fed into an existing control system.
AI-assisted analysis based on the manufacturer's specifications. Not a hands-on lab test.
Pros
- 0.1ppm resolution in the 0-50ppm band catches small changes early
- RS485 output integrates with controllers and loggers
- Waterproof wall-mounted housing suits barn conditions
- Wide DC 10-30V input simplifies wiring
Cons
- Requires a separate RS485-capable controller or logger
- Only RS485 output is confirmed for this model
- No mounting hardware or cable is listed in the box
Best for
Continuous ammonia monitoring in livestock and poultry housing with an existing RS485 control system
Not ideal for
Users wanting a standalone display unit or a handheld spot-check meter
Specifications
| Item Type | Ammonia Sensor |
|---|---|
| Model No. / Name | RS NH3 N01 2 100P 2 YL EX |
| Power Supply Voltage (V) | DC 10–30 V |
| Accuracy | ±8% (0–50ppm/0–100ppm), ±5%FS (0–500ppm @100ppm, 25℃, 50%RH) |
| Resolution | 0.1ppm (0–50ppm), 1ppm (0–100ppm/0–500ppm) |
| Operating Temperature (°C) | -20 to 50 |
| Humidity Range | 15%RH ~ 90%RH |
| Pressure Range (MPa) | 90~110kPa |
| Length (mm) | 140 |
| Width (mm) | 90 |
| Weight (g) | 133 |
| Shipping Weight | 0.168 kg |
| Shipping Dimensions | 14 × 14 × 5 cm |
What's in the box
- 1 x Renke RS-NH3-N01-2-100P-2-YL-EX ammonia sensor, RS485, 0-100ppm range
Frequently Asked Questions
What range does this ammonia sensor measure?
How does the sensor send readings?
What power supply does it need?
Where should it be installed?
What is included with the sensor?
How accurate are the readings?
Overview
The Renke RS-NH3-N01-2-100P-2-YL-EX is an industrial-grade ammonia sensor designed for air quality monitoring in livestock and poultry farms. It tracks ammonia concentration across a 0-100ppm range and reports readings through an RS485 output, making it suitable for continuous monitoring rather than occasional handheld checks. The waterproof, wall-mounted enclosure measures 140mm by 90mm and weighs 133g, so it fits neatly on barn walls, panels or equipment cabinets.
Key Features
- 0-100ppm ammonia measurement range with 0.1ppm resolution in the 0-50ppm band
- RS485 output for connecting to control and monitoring systems
- Waterproof wall-mounted housing built for farm environments
- Wide DC 10-30V power supply for flexible wiring
- Operating range of -20 to 50 degrees Celsius and 15-90%RH
- Accuracy of plus or minus 8% across the 0-100ppm range
Specifications Explained
The 0-100ppm range covers typical ammonia levels found in livestock housing, while the 0.1ppm resolution below 50ppm helps you spot small changes before they become a problem. Accuracy is stated at plus or minus 8% over 0-100ppm. The sensor works within a pressure band of 90-110kPa, matching normal atmospheric conditions.
Power is supplied from DC 10-30V, so the unit can share a supply with other farm control equipment. The RS485 interface carries readings to a controller, logger or building management system. The housing is waterproof and wall-mounted, and the operating window of -20 to 50 degrees Celsius and 15-90%RH reflects the temperature and humidity swings common in barns.
Compatibility and Requirements
Installation requires a DC 10-30V power source and an RS485-capable receiving device such as a controller or data logger. The unit is wall-mounted, so plan a flat mounting surface at the monitoring point. No other accessories are confirmed for this model.
Typical Uses
- Livestock and poultry farm air quality control
- Continuous ammonia monitoring in barns and housing
- Integration into farm ventilation and control systems via RS485
- Facility air quality record keeping
What's in the Box
1 x Renke RS-NH3-N01-2-100P-2-YL-EX ammonia sensor, RS485, 0-100ppm range.
Quick specs
- Item Type
- Ammonia Sensor
- Model No. / Name
- RS NH3 N01 2 100P 2 YL EX
- Power Supply Voltage (V)
- DC 10–30 V
- Accuracy
- ±8% (0–50ppm/0–100ppm), ±5%FS (0–500ppm @100ppm, 25℃, 50%RH)
- Resolution
- 0.1ppm (0–50ppm), 1ppm (0–100ppm/0–500ppm)
- Operating Temperature (°C)
- -20 to 50