
1 / 3 · Click to enlarge
AI Summary
The Renke RS-SO2-N01-2-20P-JK-EX is a wall-mounted sulfur dioxide sensor with RS485 output and a 0-20ppm range. Its IP67 housing and 10-30V DC input make it easy to integrate into industrial monitoring systems.
Key Highlights
- Electrochemical SO2 sensor with 0-20ppm range and 0.1ppm resolution
- RS485 output for direct connection to monitoring systems
- IP67 waterproof enclosure for harsh environments
- Wide DC 10-30V power supply with low 0.18W consumption
- Accuracy of ±5% FS and repeatability ≤2%
- Response time of 45 seconds or less at 20ppm
Ideal For
- Industrial safety managers monitoring SO2 leaks
- Environmental engineers conducting air quality surveys
- Power plant technicians tracking emission levels
- Laboratory staff working with sulfur dioxide
- HVAC specialists integrating gas detection
Buying Tip
Confirm that your monitoring system supports RS485 communication and can supply 10-30V DC power before purchasing this sensor.
Elecvora expert review
Our verdict
The Renke RS-SO2-N01-2-20P-JK-EX offers a solid combination of a quality electrochemical sensor, RS485 connectivity, and a weatherproof housing. It is a practical choice for fixed SO2 monitoring in industrial settings where low-level detection and reliable data output are required.
AI-assisted analysis based on the manufacturer's specifications. Not a hands-on lab test.
Pros
- Imported electrochemical sensor for stable measurements
- IP67 enclosure suitable for harsh environments
- RS485 output for easy system integration
- Low power consumption and wide voltage input
Cons
- Requires a separate RS485 controller or master device
- Power supply not included
- Limited to 0-20ppm range (higher ranges available in other models)
Best for
Industrial and environmental SO2 monitoring where RS485 integration is available
Not ideal for
Portable or battery-powered applications, or systems without RS485 support
Specifications
| Item Type | Sulfur Dioxide Sensor |
|---|---|
| Model No. / Name | RS SO2 N01 2 20P JK EX |
| Power Supply Voltage (V) | DC 10–30 V |
| Measurement Range | 0–20 ppm / 0–2000 ppm |
| Protection level | IP67 |
| Accuracy | ±5% FS or ±10% |
| Transmitting frequency | 76 GHz ~ 81 GHz |
| Beam Angle | 6° |
| Humidity Range | 0 ~ 95 %RH (non-condensing) |
| Avg. Power Consumption (W) | 0.18W |
| Operating Environment | -20~50℃, 15~90% RH (non-condensing) |
| Resolution | 20ppm: 0.1ppm, 2000ppm: 1ppm |
| Repeatability | ≤2% |
| Response Time(s) | 20ppm: ≤45s, 2000ppm: ≤70s |
| Shipping Weight | 0.168 kg |
| Shipping Dimensions | 14 × 14 × 6 cm |
What's in the box
- 1 x Renke RS-SO2-N01-2-20P-JK-EX Sulfur Dioxide Sensor (RS485, 0-20ppm)
- 1 x Screw Set
Frequently Asked Questions
What is the measurement range of this sensor?
What output does the sensor provide?
What power supply does it require?
Is the sensor waterproof?
What is included in the package?
What is the response time?
Overview
The Renke RS-SO2-N01-2-20P-JK-EX is a fixed sulfur dioxide sensor built for continuous monitoring of SO2 levels in industrial and environmental applications. It combines an imported electrochemical sensing element with a robust IP67-rated enclosure, making it suitable for wall-mounted installation in factories, power plants, laboratories, and chemical storage areas. The sensor outputs data via RS485, allowing straightforward integration with PLCs, building management systems, and dedicated gas monitoring controllers.
Key Features
- Imported electrochemical sensor: Provides stable and repeatable measurements with good anti-interference performance.
- 0-20ppm measurement range: Resolution of 0.1ppm for fine detection of low SO2 concentrations.
- RS485 output: Enables direct digital communication with industrial control and monitoring systems.
- IP67 protection: Waterproof and dust-tight housing for reliable operation in demanding environments.
- Wide power input: Accepts DC 10-30V, drawing only 0.18W on average.
- Fast response: Response time of ≤45 seconds at 20ppm for timely alerts.
Specifications Explained
The 0-20ppm range with 0.1ppm resolution makes this sensor well suited to detecting low-level SO2 leaks and ambient air quality monitoring. Accuracy is specified as ±5% FS (full scale), and repeatability is ≤2%, ensuring consistent readings over time. The response time of ≤45 seconds at 20ppm means the sensor reacts quickly to changing gas concentrations. Operating conditions of -20 to 50°C and 15-90% RH (non-condensing) cover most indoor and sheltered outdoor installations. The IP67 rating protects against dust and water ingress, though the sensor should not be submerged. Power consumption of 0.18W average keeps energy use minimal, and the wide 10-30V DC input allows connection to common industrial power supplies.
Compatibility and Requirements
This model provides an RS485 output for wired communication. It requires a DC power supply within the 10-30V range and a compatible RS485 master device or controller to read the sensor data. The sensor is wall-mounted and should be installed in a location that avoids direct exposure to condensing humidity. No additional adapters are included beyond the sensor and screw set.
Typical Uses
- Industrial factories monitoring for SO2 leakage
- Environmental air quality monitoring stations
- Power plants and refineries for emission control
- Laboratories handling sulfur dioxide
- Chemical storage areas for indoor air safety
- HVAC systems for gas detection and ventilation control
What's in the Box
- 1 x Renke RS-SO2-N01-2-20P-JK-EX Sulfur Dioxide Sensor (RS485, 0-20ppm)
- 1 x Screw Set

Quick specs
- Item Type
- Sulfur Dioxide Sensor
- Model No. / Name
- RS SO2 N01 2 20P JK EX
- Power Supply Voltage (V)
- DC 10–30 V
- Measurement Range
- 0–20 ppm / 0–2000 ppm
- Protection level
- IP67
- Accuracy
- ±5% FS or ±10%



















