
1 / 3 · Click to enlarge
AI Summary
The Renke RS-V10-485-G-EX converts a 0-10V analog signal into RS485 MODBUS-RTU output, letting you integrate analog sensors with PLCs and SCADA systems. It runs on 10-30V DC with minimal power draw and includes over-voltage and over-current protection.
Key Highlights
- Converts 0-10V analog input to RS485 MODBUS-RTU output
- Wide 10-30V DC power supply range
- Low power consumption of 0.4W or less
- Built-in over-voltage and over-current protection
- Selectable 10-bit or 12-bit ADC resolution
- Compact design for easy panel integration
Ideal For
- System integrators adding analog inputs to RS485 networks
- Automation technicians working with PLC and SCADA systems
- Industrial maintenance teams retrofitting legacy sensors
- Control cabinet builders needing compact signal conversion
- Data acquisition projects using MODBUS-RTU
Buying Tip
Confirm your sensor output is 0-10V and your controller supports MODBUS-RTU over RS485 before ordering this converter.
Elecvora expert review
Our verdict
The Renke RS-V10-485-G-EX is a practical, no-frills converter for bringing 0-10V signals into a MODBUS-RTU network. Its wide supply range and built-in protection make it a reliable choice for industrial integration.
AI-assisted analysis based on the manufacturer's specifications. Not a hands-on lab test.
Pros
- Wide 10-30V DC power supply
- Low power consumption (0.4W max)
- Over-voltage and over-current protection
- Selectable 10-bit or 12-bit ADC resolution
- Compact size for tight spaces
Cons
- Single input channel only
- No DIN rail mount specified
- Requires separate 10-30V DC power source
Best for
Industrial automation projects needing analog-to-RS485 conversion
Not ideal for
Applications requiring multiple analog inputs or isolated inputs
Specifications
| Shipping Weight | 0.071 kg |
|---|---|
| Shipping Dimensions | 11 × 6 × 4 cm |
What's in the box
- 1 x Renke RS-V10-485-G-EX, 0-10V to RS485 Converter, 0.4W, MODBUS-RTU
Frequently Asked Questions
What is the input signal range of this converter?
What communication protocol does it use?
What power supply does it require?
Does it have any protection features?
What is included in the package?
What is the storage temperature range?
Overview
The Renke RS-V10-485-G-EX is a dedicated signal converter for industrial environments where analog voltage readings need to join an RS485 network. It accepts a 0-10V input and transmits the measured value digitally using the MODBUS-RTU protocol, allowing PLCs, HMIs, SCADA systems, and industrial controllers to read analog sensors without additional analog input cards. The module is powered from a 10-30V DC source and consumes no more than 0.4W, so it fits comfortably into low-power control cabinets.
Key Features
- Analog-to-digital conversion: One 0-10V input channel is digitized and sent over RS485.
- MODBUS-RTU protocol: Standard industrial communication for easy integration.
- Wide supply range: Operates from 10V to 30V DC, accommodating common industrial power rails.
- Protection circuitry: Over-voltage and over-current safeguards help protect the module and connected equipment.
- Anti-interference design: Engineered for stable performance in electrically noisy settings.
- Selectable resolution: Choose between 10-bit and 12-bit ADC resolution to match your precision needs.
Specifications Explained
The 0-10V input range is common for industrial sensors and transmitters, making this converter a natural fit for legacy analog equipment. The RS485 output uses MODBUS-RTU, a widely supported protocol that lets you daisy-chain multiple devices on a single bus. The 10-30V DC power supply means the module can share the same 12V or 24V rail as other control gear, simplifying wiring. With a maximum power draw of 0.4W, heat generation is minimal and power budgets stay small. The selectable 10-bit or 12-bit ADC resolution gives you a trade-off between faster readings and finer granularity, depending on your application.
Compatibility and Requirements
The converter is designed for RS485 networks and MODBUS-RTU masters such as PLCs, HMIs, and SCADA systems. It requires a 10-30V DC power source and a 0-10V analog signal source. No additional drivers or software are specified. Ensure your RS485 bus uses standard twisted-pair wiring and proper termination for reliable communication. The module stores safely between -20°C and +60°C.
Typical Uses
- Reading analog sensors (pressure, temperature, level) into a PLC via RS485.
- Adding analog inputs to an existing MODBUS network without new analog cards.
- Industrial automation and data acquisition in control cabinets.
- Retrofitting legacy 0-10V equipment into modern SCADA systems.
What's in the Box
Package includes: 1 x Renke RS-V10-485-G-EX, 0-10V to RS485 Converter, 0.4W, MODBUS-RTU.



















